Permit Information
Permit NumberBLD06-01127
StatusFinaled
Name FALASH & ROSS CONSTRUCTION
Site Address 1010 W JEFFERSON Unit: 102
Project Name 
Customer Number 
ePlanReviewNo
Description
(Falash & Ross Const. RCE-2502) (BARKER, ROSHOLT & SIMPSON LAW OFFICE - 1010 W JEFFERSON ST - 1ST STORY) Only the basement of this building is fire sprinklered. To construct a 2,688 square foot office tenant space on the 1st story of an existing 25,745 square foot, 2 story with basement building. The building was renovated under permit BLD06-00879. Work is to include interior nonbearing walls, interior doors, millwork, suspended ceilings, and finishes. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes. The fire sprinkler system in the basement shall be maintained in compliance with NFPA 13 as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection3/1/20073/1/20073/1/2007PPASS
DetailsForrest France
Fire life safety finaled.
BLD-Final2/28/20073/1/20073/1/2007PPASS
DetailsDave Hannah
greg; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok for perm occ
Permanent Occupancy 3/1/20073/1/2007 DONE
Details
BLD-Final2/23/20072/26/20072/26/2007ACANC
DetailsDave Hannah
Scheduled by a contractor via Hello! on 2/23/2007 at 7:42:59 PM. Contact: ###-####. ok for perm occ after other trades go perm
BLD-Conference9/22/20069/22/20069/22/2006PDONE
DetailsDave Hannah
BLD-Final9/22/20069/22/20069/22/2006PPART
DetailsDave Hannah
ok for temp occ ok for perm occ after other trades go perm and sheel is finished
BLD-Other8/31/20069/1/20069/6/2006PPART
DetailsDave Hannah
This is for a Structural Fianl inspection. If you have any questions please contact Greg Bolton @ ###-####. Thanks; Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson ok for temp occ ok for perm occ after other trades go perm and shell permit is finished
BLD-Other8/31/20069/1/20069/1/2006APART
DetailsForrest France
Need to repair one emergency light at the main entrance, final pending shell and project related fire alarm permit finals.
BLD-Other8/29/20068/30/20068/30/2006AFAIL
DetailsForrest France
Fire extinguishers are not installed, missing door hardware, need suite addresses, floor and ceiling tile are not completed, need to approve fire alarm prior to life safety final, scope of work is not completed.
BLD-Other8/15/20068/15/20068/15/2006PPART
DetailsDave Hannah
greg Note: ceiling; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to drop in ceiling pannels
BLD-Framing/Rough-in8/14/20068/15/20068/15/2006APART
DetailsDave Hannah
greg ###-#### ceiling ok to drop per but need to plunb and add field wires
BLD-Other8/14/20068/14/20068/14/2006PNH
DetailsTony Young
###-#### - craIG NOTE: CEILING INSPECTION
new tile floor,, sign on door to stay out
BLD-Framing/Rough-in6/29/20066/30/20066/30/2006APASS
DetailsDave Hannah
If you have any questions please contact Greg Bolton at ###-####. Thanks; Phone #: ###-#### Internet Inspection Request from: Jennifer Jenson ok to cover