Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD06-01889
StatusFinaled
Name RA SCHULTZ AND COMPANY
Site Address 12639 W EXPLORER DR Unit: 185
Project NameEXPLORER POINTE BLDG
Customer Number 
ePlanReviewNo
Description
(R A SCHULTZ RCE # 2934 (NATIONWIDE BUSINESS CONSULTING - EXPLORER POINTE BLDG - 1ST FLR) To build-out for first time tenant, a 2,638 sq. ft. shell space as an business office for Nationwide Business Consulting. Work includes limited demolition at existing 1-hour corridor wall to relocate the existing 20 minute fire/smoke rated door assembly with 45 minute glass sidelight assembly; to infill opening in 1-hour wall with one hour construction; construct interior non-bearing walls to create private offices, conference, waiting, reception, break, storage and open office rooms or areas; furring out existing exterior walls and insulate; insulate and finish existing tenant demising wall & finish interior walls; install suspended ceiling grid system and perform electrical, mechanical, plumbing and fire sprinkler work as need for this tenant space and to comply with current adopted codes and ordinance of Boise City. Common accessible restrooms exist as part of original Shell & Core permit. All per approved plans, to include red-line notes there-on and all attached plan review conditions attached by all reviewing agencies. drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/19/20069/19/20069/19/2006PPASS
DetailsJim Sly
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
OK for Perm Occ. :)
Permanent Occupancy 9/19/20069/19/2006 DONE
Details
FIRE-Final Inspection9/18/20069/18/20069/18/2006PPASS
DetailsTroy Cobbley
Life safety finaled
BLD-Energy code compliance8/28/20068/29/20068/29/2006PPASS
DetailsJim Sly
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
BLD-Framing/Rough-in8/24/20068/25/20068/25/2006APART
DetailsMike Jordan
matt; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. elec box has been furred out at 1 hr. wall. ok to cover interior walss only. Vapor barrier required at exterior walls, insul required full height of wall also. c/n posted.
BLD-Framing/Rough-in8/22/20068/22/20068/22/2006PFAIL
DetailsJim Sly
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
OK to insulate.....They put a non rated electr panel box in 1hr corridor wall....... grid appears OK