BLD-Final | 8/13/2007 | 8/13/2007 | 8/13/2007 | P | PASS |
Mike Jordan
|
|
|
duane Note: please give a call 1 hr prior to inspection Phone #: ###-####. All issues resolved.
|
DOC - Permit Finaled | 8/13/2007 | 8/13/2007 | 8/13/2007 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 7/18/2007 | 7/18/2007 | 7/18/2007 | P | FAIL |
Mike Jordan
|
|
|
duane - please call 1 hr prior to inspection Phone #: ###-####. Install smoke alarms as shown on approved plan. Install code compliant handrails on all new stairways.
|
BLD-Final | 7/13/2007 | 7/13/2007 | 7/13/2007 | P | NR |
Mike Jordan
|
|
|
duane - please call 1 hr prior to inspection Phone #: ###-####. Needs elec. final first.
|
BLD-Energy code compliance | 4/4/2007 | 4/5/2007 | 4/5/2007 | A | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 4/4/2007 at 1:24:48 PM. Contact: ###-####. ok to cover.
|
BLD-Energy code compliance | 3/29/2007 | 3/30/2007 | 3/30/2007 | P | PASS |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 3/29/2007 at 2:55:06 PM. Contact: ###-####. FRAMING INSP. All framing issues have been repaired. will call back for energy code when complete.
|
BLD-Framing/Rough-in | 3/26/2007 | 3/27/2007 | 3/27/2007 | A | FAIL |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 3/26/2007 at 1:56:44 PM. Contact: ###-####. Landing at stairs not 36 inches. fireblock mech. chase upstairs. complete airseal package. Add studs under 2ply trusses upstairs. Swing door in upstairs or provide landing. Strap top plates above elec. boxes, 2 places. L brace gable ends. Check with joist manufacture regarding header connection supporting stairs to floor joist. Provide anchorage on bearing wall in garage and attach plywood. c/n posted. ok to insul.
|
BLD-Conference | 2/12/2007 | 2/13/2007 | 2/13/2007 | A | DONE |
Mike Jordan
|
|
|
dwayne; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. Wants to complete bonus room first. Noted to contractor to complete ri and ri insp at bonus room and then a partial framing insp. could be conducted.
|
BLD-Conference | 12/27/2006 | 12/27/2006 | 12/27/2006 | P | PASS |
Mike Jordan
|
|
|
duane; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Conference | 11/27/2006 | 11/28/2006 | 11/28/2006 | A | DONE |
Mike Jordan
|
|
|
duane; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD-Footing | 11/16/2006 | 11/17/2006 | 11/17/2006 | P | PART |
Tony Young
|
|
|
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles poured,, ok
|