Permit Information
Permit NumberBLD07-00873
StatusFinaled
Name THE RUSSELL CORPORATION
Site Address 913 W RIVER ST Unit: 200
Project NameWirestone
Customer Number 
ePlanReviewNo
Description
**(Wirestone)**(2nd Floor Suite #200)To remodel an existing 9,105 sq ft office tenant space and expand into the adjacent 2,217 sq ft space to create a 11,322 sq ft office space to occupy the entier second floor per approved plans. Work to include, removal of nonbearing partitions to enlarge offices, construction of miner interior noncombustible partitions to create new reception area, install new suspended ceiling in selective area, relocate existing lighting, patch and repair existing ceiling and flooring, miscellaneous related interior finishes. This building is fully fire sprinkled any alterations or modifications to the sprinkler system WILL REQUIRE SEPARATE PERMITS, and shall be installed per NFPA #13 as regulated by the fire department. RmH
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection2/25/20092/25/20092/25/2009APASS
DetailsTroy Cobbley
life safety passed
BLD-Final2/25/20092/25/20092/25/2009APASS
DetailsDave Hannah
ok for perm occ
FIRE-Final Inspection2/8/20082/11/20082/11/2008AFAIL
DetailsForrest France
Final pending project related fire alarm work to interconnect mag locks at the elevator lobby exit doors to the fire alarm panel and provision of access controled egress components per IFC 2003 1008.1.3.4 items 1-6.
FIRE-Final Inspection8/16/20078/16/20078/16/2007AFAIL
DetailsTroy Cobbley
There is an access controled egress door at the main exit (big door magnet). This device has not been connected to the fire alarm system. A permit will be required for this work. Also the request to exit button is by the receptionist and exceeds 5' from the door.
BLD-Other7/31/20078/1/20078/1/2007APART
DetailsDave Hannah
don; Phone #: ###-#### Internet Inspection Request from: Victoria ceiling grid ok to cover after elec and all other r/i are completed above ceiling
BLD-Framing/Rough-in6/28/20076/29/20076/29/2007APASS
DetailsTom Arcoraci
don Phone #: ###-####