Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD07-01190
StatusFinaled
Name PIONEER HOMES
Site Address 8388 W TETHER ST
Project Name 
Customer Number 
ePlanReviewNo
Description
Contractor Registration provided by Aaron Dressen RCE-4897. To construct a 3068 sq.ft. two story single family dwelling (1280 sq.ft. first floor / 1788 sq.ft. second floor) with a 1125 sq.ft. attached two car garage, 226 sq.ft. covered rear porch, and a 49 sq.ft. covered front entry. THE PERMIT HOLDER is responsible to comply with current wall bracing requirements as adopted by Boise City. Approval is based on approved plans, redlinning, rescheck, and plan review report. Zoning approved by Sue Hansen as R-1B/DA. No fire sprinklers per Sam Rogers. TLW
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/14/20078/15/20078/15/2007APASS
DetailsMike Jordan
Ben; call for access; Phone #: ###-#### Internet Inspection Request from: Hattie James
DOC - Permit Finaled8/15/20078/15/20078/15/2007PPASS
DetailsMike Jordan
BLD-Energy code compliance7/2/20077/3/20077/3/2007PPASS
DetailsMike Jordan
paul; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang. All issues resolved. ok to cover.
BLD-Framing/Rough-in7/3/20077/3/20077/3/2007PCANC
DetailsMike Jordan
Scheduled by a contractor via Hello! on 7/3/2007 at 7:21:48 AM. Contact: ###-####.
BLD-Conference7/3/20077/3/20077/3/2007AFAIL
DetailsMike Jordan
ENERGY CODE INSP. Needs to provide R38 batts in attic upstairs. c/n posted. not ok to cover framing.
BLD-Framing/Rough-in7/2/20077/3/20077/3/2007APASS
DetailsMike Jordan
paul; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang. All framing issues have been resolved.
BLD-Framing/Rough-in6/28/20076/29/20076/29/2007PFAIL
DetailsMike Jordan
Scheduled by a contractor via Hello! on 6/28/2007 at 7:45:31 AM. Contact: ###-####. Finish nailing off simpson hangars upstairs. Provide approved repair for floor joist were cut at end. Provide mech. connection on 2 ply at garage. c/n posted. ok to insul.
BLD-Foundation5/31/20075/31/20075/31/2007PPASS
DetailsMike Jordan
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Column pad footings added.
BLD-Footing5/30/20075/30/20075/30/2007PPART
DetailsMike Jordan
matt; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Needs to add column pad footings at garage for piont loads as red lined on approved drawings. Will confirm on wall placement.
BLD-Footing5/29/20075/30/20075/30/2007ANR
DetailsMike Jordan
matt; Phone #: ###-#### Internet Inspection Request from: Victoria Beall. hole is being dug.