BLD-Final | 6/27/2008 | 6/27/2008 | 6/27/2008 | P | PASS |
Mike Jordan
|
|
|
Nancy Phone #: ###-####
|
DOC - Permit Finaled | 6/27/2008 | 6/27/2008 | 6/27/2008 | P | PASS |
Mike Jordan
|
|
|
HAnrail repaired. Letter of compliance issued.
|
BLD-Final | 6/26/2008 | 6/26/2008 | 6/26/2008 | P | FAIL |
Mike Jordan
|
|
|
Nancy Phone #: ###-####. Needs to raise handrail to meet 34-38 inch height.
|
BLD - Request for Extension | 12/28/2007 | 12/28/2007 | 12/28/2007 | | PASS |
Mike Jordan
|
|
|
Only thing not ready is the plumbin - nancy - ###-####. work has been ongoing with no interuptions. ok to exttend 90 days.
|
BLD-Framing/Rough-in | 12/4/2007 | 12/4/2007 | 12/4/2007 | P | PASS |
Mike Jordan
|
|
|
Nancy, late afternoon please; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
|
BLD-Framing/Rough-in | 11/26/2007 | 11/26/2007 | 11/26/2007 | P | PART |
Mike Jordan
|
|
|
nancy Phone #: ###-####. Framing ok, pend. elec. and plumbing ri insp.
|
BLD-Energy code compliance | 10/24/2007 | 10/25/2007 | 10/25/2007 | A | PASS |
Mike Jordan
|
|
|
nancy Phone #: ###-####. Stud shoes installed. insul ok. ok to cover.
|
BLD-Framing/Rough-in | 10/23/2007 | 10/24/2007 | 10/24/2007 | A | PASS |
Mike Jordan
|
|
|
nancy Phone #: ###-####. ok to insul. All issues resolved, except that boots still need to be installed.
|
BLD-Framing/Rough-in | 10/15/2007 | 10/15/2007 | 10/15/2007 | P | FAIL |
Mike Jordan
|
|
|
nancy Phone #: ###-####. Needs to complete air seal package, Add additional blocking under 2ply in basement, provide boots on studs at plumbing penetrations at wall by stairs to basement. Provide smoke detector in basement, Needs elec and mech ri insp. prior to proceeding.
|
BLD-Framing/Rough-in | 9/4/2007 | 9/4/2007 | 9/4/2007 | P | PART |
Mike Jordan
|
|
|
nancy Phone #: ###-####. Did prelim walkthrough. Will need to get ri insp. and call for framing insp.
|
BLD-Conference | 8/9/2007 | 8/9/2007 | 8/9/2007 | P | DONE |
Mike Jordan
|
|
|
nancy - as soon as possible Phone #: ###-####. Noted to homeowner that a beam would be required to carry gable end truss. Also noted to homeowner to contact truss engineer for correct size applications.
|
BLD-Conference | 8/1/2007 | 8/2/2007 | 8/2/2007 | A | DONE |
Mike Jordan
|
|
|
Nancy; Phone #: ###-#### Internet Inspection Request from: Darla Downs. Checked egress windows, can be smaller, and winder stairs. Winders do not meet code, also headroom issues. ok to make stairs straight.
|
BLD-Wall cover | 7/13/2007 | 7/13/2007 | 7/13/2007 | P | PART |
Mike Jordan
|
|
|
cody - wall Phone #: ###-####
|
BLD-Footing | 7/10/2007 | 7/10/2007 | 7/10/2007 | P | PASS |
Mike Jordan
|
|
|
cody; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
|