BLD-Final | 10/20/2009 | 10/21/2009 | 10/20/2009 | A | PASS |
Jim Sly
|
|
|
bryan Phone #: ###-#### OK for Perm Occ.
|
FIRE-Final Inspection | 10/20/2009 | 10/20/2009 | 10/20/2009 | P | PASS |
Troy Cobbley
|
|
|
Life safety passed.
|
BLD-Final | 10/19/2009 | 10/19/2009 | 10/19/2009 | P | NR |
Jim Sly
|
|
|
Bryan phone ###-#### Need fire final.
|
FIRE-Final Inspection | 10/5/2009 | 10/6/2009 | 10/6/2009 | A | FAIL |
Troy Cobbley
|
|
|
The occupant load signs have been mounted and the exit signs, emergency lighting and exit discharge lighting have been verified for functionality. One emergency light and one exit sign need repaired as discussed. See the 10/5/2009 entry for other items needing addressed prior to a final sign off. The relocation of the generator is ok per scott and the fire alarm panel can provide supervision of the primary power at the horizontal sliding doors per Jason Blaise.
|
FIRE-Final Inspection | 10/1/2009 | 10/5/2009 | 10/5/2009 | P | FAIL |
Troy Cobbley
|
|
|
The project related fire sprinkler and fire alarm permits need to be finaled, both of the horizontal sliding doors need to be adjusted so that they easily open manually, the atrium smoke evacuation system needs to be addressed, the exit discharge lighting needs to be removed from control by the photocells and electrical super vision of the horizontal sliding doors needs to be addressed. All of the exit signs, emergency lights and exit discharge lights need to be inspected for placement and tested for functionality after the generator switch over has been repaired. Also need to verify that the relocation of the emergency generator is ok with plan review.
|
BLD-Final | 9/15/2009 | 9/16/2009 | 9/16/2009 | A | PEND |
Jim Sly
|
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan Herb Walk-thru all sleeping units.........OK. Need all Req. signatures for final.
|
BLD-Other | 9/10/2009 | 9/14/2009 | 9/14/2009 | P | PASS |
Jim Storey
|
|
|
Drop ceiling grid inspection Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Other | 8/24/2009 | 8/25/2009 | 8/25/2009 | A | NR |
Jim Sly
|
|
|
suspended ceiling Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Wall cover | 5/7/2009 | 5/8/2009 | 5/10/2009 | P | PASS |
Jim Sly
|
|
|
1st floor sheetrock nailing Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Energy code compliance | 4/23/2009 | 4/24/2009 | 4/24/2009 | A | PASS |
Jim Sly
|
|
|
1st floor insulation Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Wall cover | 4/21/2009 | 4/22/2009 | 4/22/2009 | P | PASS |
Jim Sly
|
|
|
2nd floor sheetrock nailing Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Framing/Rough-in | 4/16/2009 | 4/16/2009 | 4/16/2009 | P | PART |
Jim Sly
|
|
|
Brian Phone 2nd flr OK
|
BLD-Energy code compliance | 4/15/2009 | 4/16/2009 | 4/16/2009 | A | CANC |
Jim Sly
|
|
|
2nd floor insulation Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Wall cover | 4/14/2009 | 4/15/2009 | 4/15/2009 | A | PASS |
Jim Sly
|
|
|
sheetrock Phone #: ###-#### Internet Inspection Request from: Bryan Herb 3rd flr ok
|
BLD-Wall cover | 4/7/2009 | 4/7/2009 | 4/7/2009 | P | PART |
Jim Sly
|
|
|
1st floor inspection to insulate Phone #: ###-#### Internet Inspection Request from: Bryan Herb......OK
|
BLD-Energy code compliance | 4/6/2009 | 4/7/2009 | 4/7/2009 | P | PART |
Jim Sly
|
|
|
For 3pm if possible. Thanks Phone #: ###-#### Internet Inspection Request from: Bryan Herb 3rd Floor OK
|
BLD-Wall cover | 4/2/2009 | 4/3/2009 | 4/3/2009 | A | PASS |
Jim Sly
|
|
|
2nd floor Phone #: ###-#### Internet Inspection Request from: Bryan Herb 2nd floor OK to cover
|
BLD-Wall cover | 3/23/2009 | 3/25/2009 | 3/25/2009 | A | FAIL |
Jim Sly
|
|
|
inspection to insulate all three floors of B wing. Phone #: ###-#### Internet Inspection Request from: Complete firestopping.
|
BLD-Conference | 3/18/2009 | 3/19/2009 | 3/19/2009 | A | CANC |
Jim Sly
|
|
|
|
BLD-Conference | 3/17/2009 | 3/19/2009 | 3/19/2009 | A | DONE |
Jim Sly
|
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Wall cover | 3/17/2009 | 3/17/2009 | 3/17/2009 | P | PART |
Jim Sly
|
|
|
Would like to sheet rock 3rd floor ceiling. Phone #: ###-#### Internet Inspection Request from: Bryan Herb 3rd Flr ceiling OK
|
FIRE-Sprinkler Rough-in | 3/17/2009 | 3/17/2009 | 3/17/2009 | P | PASS |
Troy Cobbley
|
|
|
A sprinkler inspection was performed on the attic dry system for Building B. The attic system in building B can be covered. See the city approved plans, FIR08-00831, for the specific area. The inspection report is being made under the building permit due to the sprinkler permit being in the review status for wet system changes requiring resubmittals.
|
FIRE-Sprinkler Rough-in | 3/17/2009 | 3/17/2009 | 3/17/2009 | A | PASS |
Troy Cobbley
|
|
|
A sprinkler inspection was performed on the attic dry system for Building B. See the city approved sprinkler plans for locations where three sprinkler heads need to be added. The inspection report is being made under the building permit due to the sprinkler permit being in the review status for wet system changes requiring resubmittals.
|
BLD-Framing/Rough-in | 2/24/2009 | 2/25/2009 | 2/25/2009 | A | PART |
Jim Sly
|
|
|
hallway insulation inspection Phone #: ###-#### Internet Inspection Request from: Bryan Herb OK to cover hallway ceilings 1st and 2nd flr.
|
BLD-Conference | 2/19/2009 | 2/20/2009 | 2/20/2009 | A | DONE |
Jim Sly
|
|
|
Herb phone
|
BLD-Framing/Rough-in | 2/19/2009 | 2/19/2009 | 2/19/2009 | P | PART |
Jim Sly
|
|
|
Herb phone Epoxy hold down inspection.....OK pending MTI special insp, tests, and approvals.
|
BLD-Framing/Rough-in | 2/18/2009 | 2/19/2009 | 2/19/2009 | A | NR |
Jim Sly
|
|
|
ATS holddown system. MTI is scheduled to begin their inspection about 10 if you want to be here. Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Framing/Rough-in | 2/17/2009 | 2/17/2009 | 2/17/2009 | P | FAIL |
Jim Sly
|
|
|
fire caulk reinspection for hallways Phone #: ###-#### Internet Inspection Request from: Bryan Herb Minor Corrections 1st and 2nd floors
|
BLD-Framing/Rough-in | 2/12/2009 | 2/13/2009 | 2/13/2009 | A | FAIL |
Jim Sly
|
|
|
fire caulk inspection prior to hallway insulation Phone #: ###-#### Internet Inspection Request from: Bryan Herb Need UL listings For All Penitrating items.
|
BLD-Foundation | 2/9/2009 | 2/10/2009 | 2/10/2009 | A | PASS |
Jim Sly
|
|
|
Scheduled by a contractor via Hello! on 2/9/2009 at 1:55:57 PM. Contact: ###-####. Foundation for bus garages OK......Garages shown on plan, but not included in scope of work (verbage) on any of the (3) permits for this project. Brian said he would contact PDS and verify OK.
|
BLD-Conference | 2/5/2009 | 2/6/2009 | 2/6/2009 | A | DONE |
Jim Sly
|
|
|
look at penetrations and discuss before we start fire caulking Phone #: ###-#### Internet Inspection Request from: Bryan Herb
|
BLD-Conference | 2/5/2009 | 2/6/2009 | 2/5/2009 | A | CANC |
Jim Sly
|
|
|
discuss fire protection before we begin fire caulking. Phone #: ###-#### Internet Inspection Request from: Bryan Herb Inspection cancelled from web by: Bryan Herb
|
BLD-Framing/Rough-in | 1/22/2009 | 1/26/2009 | 1/26/2009 | P | PART |
Jim Sly
|
|
|
interior sheer wall Phone #: ###-#### Internet Inspection Request from: Bryan Herb Interior Shear wall nailing at "B" wing...3 floors OK.
|
BLD-Framing/Rough-in | 1/8/2009 | 1/12/2009 | 1/12/2009 | A | PART |
Jim Sly
|
|
|
shearwall and roof inspection Phone #: ###-#### Internet Inspection Request from: Bryan Herb Exterior nailing at "B" wing (walls and Roof) OK
|
BLD-Framing/Rough-in | 12/31/2008 | 1/5/2009 | 1/5/2009 | A | CANC |
Jim Sly
|
|
|
Exterior sheer nailing Phone #: ###-#### Internet Inspection Request from: Bryan Herb Canc by Contr....
|
BLD-Conference | 12/4/2008 | 12/8/2008 | 12/8/2008 | A | DONE |
Jim Sly
|
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan Herb Met with Bryan, Mike and Rich (the framer)....Mike Phone ###-####
|
BLD-Concrete | 10/31/2008 | 10/31/2008 | 10/31/2008 | P | PART |
Jim Sly
|
|
|
interior footing rebar Phone #: ###-#### Internet Inspection Request from: Bryan Herb MTI on site
|
BLD-Concrete | 10/23/2008 | 10/24/2008 | 10/24/2008 | P | PART |
Jim Sly
|
|
|
Flat work prep Phone #: ###-#### Internet Inspection Request from: Bryan Herb MTI on site
|
BLD-Energy code compliance | 10/1/2008 | 10/3/2008 | 10/3/2008 | A | PART |
Jim Sly
|
|
|
If possible would like inspection around 10am for continued foundation insulation. Phone #: ###-#### Internet Inspection Request from: Bryan Herb Foundation insulation West wall OK.
|
BLD-Energy code compliance | 9/29/2008 | 10/1/2008 | 10/1/2008 | A | PART |
Jim Sly
|
|
|
Foundation insulation inspection for backfill. Phone #: ###-#### Internet Inspection Request from: Bryan Herb Appears OK.
|
BLD-Foundation | 9/25/2008 | 9/26/2008 | 9/26/2008 | P | PART |
Jim Sly
|
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan Herb Wall OK Pend MTI insp and approvals
|
BLD-Footing | 9/23/2008 | 9/23/2008 | 9/23/2008 | P | CANC |
Jim Sly
|
|
|
Brian Phone #: ###-####
|
BLD-Footing | 9/22/2008 | 9/23/2008 | 9/23/2008 | A | PART |
Jim Sly
|
|
|
bryan Phone #: ###-#### East 3rd of Bldg #3 footings OK 2500 psi design...... Special insp cylinders MTI MTI approval for Sub Grade.
|