Permit Information
Permit NumberBLD08-00102
StatusFinaled
Name ST ALPHONSUS REGIONAL MEDICAL CNTR
Site Address 1055 N CURTIS RD
Project Name 
Customer Number 
ePlanReviewNo
Description
NO GC- Architect will act as general ///dld (SARMC Staff Training Area) To change the occupancy use of a 8,875 sq. ft. portion of the previous 21,000 sq. ft. operating rooms / support areas to be used as staff training facilities. This area is located on the first floor of the South Tower of St. Al's. The building is fully sprinklered and has an alarm system. Computer work stations will be installed in 13 existing rooms, with 14 stations in each of rooms #1 thru #10; 11 stations in room designated P2; 16 stations in room #11; and 18 practice stations for staff use outside of the normal classroom training, a total of 185 work training stations. Each class room has access to two exits, one exit access door directly into an existing exit corridor and one through intervening rooms. The main corridors have one exit directly to the exterior at the south end and a a set of exit doors into an existing rated corrridor serving as a primary exit of the south tower first floor. Exit signage and emergency egress illumination are existing and are to be maintained. All door hardware from the training rooms & conference room areas and along the path of egress travel serving these rooms, are required to comply with Section 1008.1.8, 2006 IBC, having door hardware "...readily openable from the egress side without use of a key or special knowledge or effort. Scope of work includes upgrade to alarm system to meet current code. Separate application, plans, approval & permit is required before any work pertaining to the alarm system can begin. The existing sprinkler and alarm system are to remain fully functional at all times. drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/13/20085/13/20085/13/2008PPASS
DetailsTom Arcoraci
dennis Phone #: ###-####
FIRE-Sprinkler Rough-in5/12/20085/13/20085/13/2008APASS
DetailsTroy Cobbley
Life safety passed.
FIRE-Final Inspection5/12/20085/13/20085/13/2008APASS
DetailsTroy Cobbley
Permit finaled
BLD-Final2/6/20082/6/20082/6/2008PPART
DetailsTom Arcoraci
dennis Phone #: ###-#### ok for temp occ
FIRE-Final Inspection2/5/20082/6/20082/6/2008APART
DetailsTroy Cobbley
A temporary occupancy was given with sam rogers permisson. The existing chimes had a sound level between 65 and 70 db. Fire extinguishers, exit lights and emergency lighting is in place. The fire alarm permit will need to be finaled prior to a final inspection for this building permit.