BLD-Final | 8/29/2008 | 9/2/2008 | 9/2/2008 | A | PASS |
Mike Jordan
|
|
|
Will Phone #: ###-####. Cert of occ. issued.
|
DOC - Permit Finaled | 9/2/2008 | 9/2/2008 | 9/2/2008 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Energy code compliance | 6/5/2008 | 6/6/2008 | 6/6/2008 | A | PASS |
Mike Jordan
|
|
|
will Phone #: ###-####. All framing issues resolved.
|
BLD-Framing/Rough-in | 6/3/2008 | 6/3/2008 | 6/3/2008 | P | PART |
Mike Jordan
|
|
|
will Phone #: ###-####. Still need paperwork for FBI at bonusroom roof, and fix for GE4 truss above garage door.
|
BLD-Framing/Rough-in | 5/28/2008 | 5/28/2008 | 5/28/2008 | P | FAIL |
Mike Jordan
|
|
|
Entire exterior must have weather resitive barrier. Complete fireblocking on all furouts and fur downs. Additional studs needed at TG2 two ply truss. Nail off all simpson hangars. Provide min. 3 nails in truss to top plate connection. Provide additional engineering and details at bonus room joisand tie in, also need to address ventilation in this area. c/n posted.
|
BLD-Framing/Rough-in | 5/27/2008 | 5/28/2008 | 5/28/2008 | A | NR |
Mike Jordan
|
|
|
will Phone #: ###-####. rescheduled for this afternoon after elec. ri insp.
|
BLD-Footing | 4/2/2008 | 4/3/2008 | 4/3/2008 | A | PART |
Mike Jordan
|
|
|
Scheduled by a contractor via Hello! on 4/2/2008 at 10:29:54 AM. Contact: ###-####. wip. Needs to install verts at garage footing.
|