Information based on query as of Thursday, July 18, 2024.
Permit Information
Permit NumberBLD08-02199
StatusFinaled
Name PARADIGM CONSTRUCTION COMPANY LLC
Site Address 560 S BLUE PINE LN
Project NamePinetree Village
Customer Number 
ePlanReviewNo
Description
(Unit 2 Building 14) This permit is for the construction of a new townhouse with four attached units. This is unit 2 that has a total of 1396 square feet with an attached garage of 431 square feet. The main level is 624 square feet with one bathroom, a kitchen, and a covered front porch of 48 square feet. The second story is a total of 772 with three bedrooms and two bathrooms. The separation wall will continue to the end of the wall that separates the front porches and continue through to the roof deck as noted on plans. Epoxy anchors are being used on the interior walls and these will require a special inspector's sign off that will be provided to the City of Boise inspector on site. SEE COMMENTS FOR ANCHOR INFO. The furnace has been placed in the attic space and will require a walkway in the attic and a working platform, see attached plan review report for details. The separation wall is built to WP 4136 as noted and detailed on the approved plans. This two hour wall may not have any penetrations, the columns in the garage must be placed inside the separation wall. R-2D zoning district, building setbacks, CUP07-00150, CUP08-00058, and DRH08-00043 per Planning and Zoning. Built per all approved plans, red lining, engineering and plan review report. (BSP)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/30/200911/30/200911/30/2009APASS
DetailsMike Jordan
call Jim Phone #: ###-#### Internet Inspection Request from: James Larkin
DOC - Permit Finaled11/30/200911/30/200911/30/2009PPASS
DetailsMike Jordan
Cert. of occ was issued.
BLD-Other4/3/20094/3/20094/3/2009PCANC
DetailsMike Jordan
Jim- building wrap Phone #: ###-####
BLD-Framing/Rough-in3/18/20093/18/20093/18/2009PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 3/18/2009 at 6:21:22 AM. Contact: ###-####. Inspected remaining 5/8 type x rock in garages for 2hr. fire walls. Also verified installation of exterior water resistive barrier.
BLD-Energy code compliance3/12/20093/13/20093/13/2009APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 3/12/2009 at 8:37:30 PM. Contact: ###-####. ok to rock.
BLD-Framing/Rough-in3/11/20093/11/20093/11/2009PPASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 3/11/2009 at 7:15:27 AM. Contact: ###-####. ok to insul.
BLD-Energy code compliance3/10/20093/11/20093/11/2009PCANC
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Framing/Rough-in2/23/20092/23/20092/23/2009PPASS
DetailsMike Jordan
jim Phone #: ###-####. 1st. layer of 5/ 8 type x rock from ceiling to roof deck, both sides.
BLD-Framing/Rough-in2/19/20092/20/20092/20/2009PNR
DetailsMike Jordan
Scheduled by a contractor via Hello! on 2/19/2009 at 9:59:51 PM. Contact: ###-####.
BLD-Framing/Rough-in2/19/20092/19/20092/19/2009PPASS
DetailsMike Jordan
jim - firewalls Phone #: ###-####. Verified firerated plywood at 4ft. laydown parapet at overbuild areas...ok.
BLD-Framing/Rough-in2/18/20092/19/20092/19/2009APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 2/18/2009 at 5:08:48 PM. Contact: ###-####. nailing for type x rock at over build areas ok.
BLD-Framing/Rough-in2/18/20092/18/20092/18/2009PPASS
DetailsMike Jordan
Jim Phone #: ###-####. 2nd floor, 2nd layer, both sides type x rock for 2hr. wall.
BLD-Framing/Rough-in2/17/20092/17/20092/17/2009PPART
DetailsMike Jordan
Jim- Fire wall Phone #: ###-####. 2nd. floor, 1st. layer of 5/8 type x rock for 2hr. wall.
BLD-Framing/Rough-in2/11/20092/13/20092/13/2009PNR
DetailsMike Jordan
jim - fire wall Phone #: ###-####
BLD-Framing/Rough-in2/10/20092/11/20092/11/2009PPASS
DetailsMike Jordan
Jim Phone #: ###-####. 1st. floor, 2nd layer 5/8 type x rock for 2hr. wall. both sides.
BLD-Framing/Rough-in2/10/20092/11/20092/11/2009APART
DetailsMike Jordan
Jim Phone #: ###-####. 1st. floor, 5/8 type x rock, for 2hr. wall remaining side.
BLD-Framing/Rough-in2/10/20092/10/20092/10/2009PPART
DetailsMike Jordan
Jim Phone #: ###-####. 1st. floor, 5/8 type X rock for 2hr. wall, one side only.
BLD-Footing2/4/20092/5/20092/5/2009APASS
DetailsMike Jordan
Scheduled by a contractor via Hello! on 2/4/2009 at 2:52:23 PM. Contact: ###-####. Interior footings.
BLD-Energy code compliance1/23/20091/23/20091/23/2009PPASS
DetailsMike Jordan
jim Phone #: 861-024. Rigid insul. at interior side of stemwall.
BLD-Foundation1/22/20091/22/20091/22/2009PPASS
DetailsMike Jordan
BLD-Foundation1/21/20091/22/20091/22/2009ANR
DetailsMike Jordan
bill Phone #: ###-####. Rescheduled for pm.
BLD-Footing1/20/20091/21/20091/21/2009APASS
DetailsMike Jordan