Information based on query as of Tuesday, July 16, 2024.
Permit Information
Permit NumberBLD08-02206
StatusFinaled
Name PARADIGM CONSTRUCTION COMPANY LLC
Site Address 8907 W EVENING STAR LN
Project NamePinetree Village
Customer Number 
ePlanReviewNo
Description
(Unit 2 Building 15) This permit is for the construction of a new townhouse with three attached units. This is unit 2 that has a total of 1396 square feet with an attached garage of 431 square feet. The main level is 624 square feet with one bathroom, a kitchen, and a covered front porch of 48 square feet. The second story is a total of 772 with three bedrooms and two bathrooms. Epoxy anchors are being used on the interior walls and these will require a special inspector's sign off that will be provided to the City of Boise inspector on site. SEE COMMENTS FOR ANCHOR INFO. The furnace has been placed in the attic space and will require a walkway in the attic and a working platform, see attached plan review report for details. The separation wall is build to WP4136 as noted and detailed on the approved plans. This two hour wall may not have any penetrations, the columns in the garage must be placed inside the separation wall. R-2D zoning district, building setbacks, CUP07-000150, CUP08-00058, and DRH08-00043 per Planning and Zoning. Built per all approved plans, red lining, engineering and plan review report. (BSP)
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final12/1/200912/1/200912/1/2009PPASS
DetailsMike Jordan
DOC - Permit Finaled12/1/200912/1/200912/1/2009PPASS
DetailsMike Jordan
Cert. of occ issued.
BLD-Final12/1/200912/1/200912/1/2009ANR
DetailsMike Jordan
Phone #: ###-#### Internet Inspection Request from: James Larkin. Moved to PM.
BLD-Other4/3/20094/3/20094/3/2009PPASS
DetailsMike Jordan
Jim- building wrap Phone #: ###-####. Verified installation of weather resistive barrier. ok.
BLD-Framing/Rough-in3/9/20093/9/20093/10/2009PCANC
DetailsMike Jordan
Jim Phone #: ###-####
BLD-Energy code compliance3/6/20093/9/20093/9/2009APASS
DetailsMike Jordan
Jim Phone #: ###-####. ok to rock.
BLD-Framing/Rough-in3/5/20093/5/20093/5/2009PPASS
DetailsMike Jordan
jim Phone #: ###-####. ok to insul.
BLD-Energy code compliance3/5/20093/5/20093/5/2009PCANC
DetailsMike Jordan
jim Phone #: ###-####
BLD-Framing/Rough-in2/23/20092/23/20092/23/2009PCANC
DetailsMike Jordan
jim Phone #: ###-####
BLD-Framing/Rough-in2/19/20092/20/20092/20/2009PCANC
DetailsMike Jordan
Scheduled by a contractor via Hello! on 2/19/2009 at 10:02:21 PM. Contact: ###-####.
BLD-Framing/Rough-in2/19/20092/19/20092/19/2009PNR
DetailsMike Jordan
jim - firewalls Phone #: ###-####
BLD-Framing/Rough-in2/18/20092/19/20092/19/2009APART
DetailsMike Jordan
Scheduled by a contractor via Hello! on 2/18/2009 at 5:13:16 PM. Contact: ###-####. 1st. layer type x rock for 2hr. wall from ceiling to roof deck, also verified nailing on type x rock at overbuild sections and rated plywood for 4ft. parapet at overbuild sections.
BLD-Framing/Rough-in2/18/20092/18/20092/18/2009PPASS
DetailsMike Jordan
Jim Phone #: ###-####. 2nd floor, 2nd layer, both sides type x rock for 2hr. wall.
BLD-Framing/Rough-in2/17/20092/17/20092/17/2009PPART
DetailsMike Jordan
Jim- Fire wall Phone #: ###-####. 2nd. floor, remaining side.
BLD-Framing/Rough-in2/11/20092/13/20092/17/2009PPART
DetailsMike Jordan
jim - fire wall Phone #: ###-####. 2nd. floor, 5/8 type x rock one side for 2hr. fire wall.
BLD-Framing/Rough-in2/10/20092/11/20092/11/2009PPASS
DetailsMike Jordan
Jim Phone #: ###-####. 1st. floor, 2nd. layer of 5/8 type x rock for 2hr. wall, both sides.
BLD-Framing/Rough-in2/10/20092/11/20092/11/2009APART
DetailsMike Jordan
Jim Phone #: ###-####. 1st. floor, 5/8 type x rock for 2hr. wall remaining side.
BLD-Framing/Rough-in2/10/20092/10/20092/10/2009PPART
DetailsMike Jordan
Jim Phone #: ###-####. 1st. floor, 5/8 type x rock on 2hr. wall. one side only.
BLD-Energy code compliance1/23/20091/23/20091/23/2009PPASS
DetailsMike Jordan
jim Phone #: ###-####. Rigid insul. at interior side of stemwall.
BLD-Foundation1/22/20091/22/20091/22/2009PPASS
DetailsMike Jordan
BLD-Foundation1/21/20091/22/20091/22/2009ANR
DetailsMike Jordan
bill Phone #: ###-####. Rescheduled for pm.
BLD-Framing/Rough-in1/22/20091/22/20091/22/2009PCANC
DetailsMike Jordan
BLD-Footing1/20/20091/21/20091/21/2009APASS
DetailsMike Jordan
Jim-###-####. Exterior perimeter footings.