Permit Number | BLD09-00721 |
Status | Finaled |
Name |
FRANK STARMAN
|
Site Address |
5122 W FAIRVIEW AVE
|
Project Name | |
Customer Number | |
ePlanReview | No |
Description |
( Finer Floors Racking ) This permit is for steel racking. Permit to install approximatel 250 sq. ft. of racking for high piled storage of carpeting products. Installation to be done per the approved plans and attached engineering. Work to include installation of prefabricated 16 foot tall storage racking including seismic bolting to an existing slab. Approval of this permit is contingent upon adhering to approved plans and engineeering. The design, testing and utilization of industrial steel storage racks shall be in accordance with the RMI Specification for the design, testing and utilizaton of industrial steel storage racks. (SPECIAL INSPECTIONS ON THE ANCHOR BOLTS ARE REQUIRED PER THE ENGINEERING.)No occupancy allowed under this permit. No seperate review comments attached. HPS is less than 500 sq.ft. Storage shall maintain 24 inch clear space from top of storage to ceiling. This building is not fire sprinklered. CDM/SJA
|