Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberBLD09-02048
StatusFinaled
Name HILL CONSTRUCTION CO
Site Address 3852 N EAGLE RD
Project NameBoise First Church of the Naza
Customer Number 
ePlanReviewNo
Description
(THE CHILDREN'S ACADEMY PRE-SCHOOL) (Boise First Church of the Nazarene) Minor remodel at SW corner of 2nd floor to convert former Classroom 'B' occupancy areas for shared use as Pre-School 'E' occupancy child care use areas, Monday thru Friday per approved plans. This childcare is for use for children more than 2-1/2 years of age. Work to include select interior demolition between Classrooms 236 & 237, combining into one room, #236, of 1,140 sq. ft. childcare with 196 sq. ft. storage area, max. occupant load 33. The combining of the rooms provides the required two exits for the room with an occupant load greater than 10. A partial height wall with double doors is being constructed in the south end of this room to create an 196 sq. ft. storage room. Rooms 232 & 233 are combined to be room #232 for childcare, 818. sq. ft., max. occ. load 23; rooms 234 & 235 are combined to be room #234 for childcare, 917 sq. ft., max. occ. load 26; rooms 238/239 combined to be room 238, 1,124 sq. ft., max. occ. load 32, but the maximum occupant load of all rooms added together per CUP09-00037 CANNOT exceed 60. The occupant loads noted under the IBC were used to determine exiting, sprinkler, alarm and restroom requirements for the childcare area, not to determine the allowed occupant load - CUP09-00037 controls allowed occupant load. When these rooms are used for childcare Monday thru Friday, the accordian wall room dividers CANNOT be pulled to divide the rooms. Dividing the rooms would create a life safety issue for access to the required two exits as the determined occupant load of each room is greater than 10. Occupant load is established by dividing the square footage of each room by 35 occupant load factor to determine building code requirements for number of exits, exit signage, emergency lighting, sprinkler, alarm and plumbing fixture requirements. The total allowed combined occupant load for all new childcare rooms (132/133; 134/135; 136/137; and 138/139) created under this permit are limited based on the CUP Mod. application creating CUP09-00037 (Xref. CUP00-00029) for an approved occupant load of "60" for the second floor childcare area. NOTE: This childcare area is in addition to the existing childcare located on the first floor, north end in rooms, #113 (26 o.l.), #115 (26 o.l.), #117/118/119 (26 o.l.) & #123 (33 o.l.) created under BLD03-01736, C.O. #9773, for 111 children. As part of the Sunday worship services, the classrooms can be used based on original occupant loads assigned under BLD03-03711, and room dividers can be used as long as room occupant load does not exceed 49 in any one room. CUP09-00037 drs
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/19/20105/20/20105/20/2010PPASS
DetailsJim Sly
church office contact - Naomi Fullwood Inspection requested from web by: Pam Bullock Phone #: ###-####
OKfor perm occ.
FIRE-Final Inspection5/19/20105/20/20105/20/2010APASS
DetailsTroy Cobbley
Life safety passed.
BLD-Final5/18/20105/19/20105/19/2010PNR
DetailsJim Sly
Pam Bullock Inspection requested from web by: Pam Bullock Phone #: ###-####
Need fire final