BLD-Final | 2/11/2010 | 2/12/2010 | 2/12/2010 | A | PASS |
Mike Jordan
|
|
|
Eric-Please call for access information Phone #: ###-####
|
DOC - Permit Finaled | 2/12/2010 | 2/12/2010 | 2/12/2010 | P | PASS |
Mike Jordan
|
|
|
Cert. of occ. was issued.
|
BLD-Energy code compliance | 1/15/2010 | 1/19/2010 | 1/19/2010 | A | PASS |
Mike Jordan
|
|
|
Eric Phone #: ###-####
|
BLD-Framing/Rough-in | 1/19/2010 | 1/19/2010 | 1/19/2010 | A | PASS |
Mike Jordan
|
|
|
Eric Phone #: ###-####. Reviewed new truss engineering and inspected 2ply truss fix. ok. Also verified the 2 layers of 5/8 type x rock at soffitts. ok. all issues resolved.
|
BLD-Framing/Rough-in | 1/15/2010 | 1/15/2010 | 1/15/2010 | P | NR |
Mike Jordan
|
|
|
eric Phone #: ###-####
|
BLD-Energy code compliance | 1/15/2010 | 1/15/2010 | 1/15/2010 | P | NR |
Mike Jordan
|
|
|
eric Phone #: ###-####
|
BLD-Framing/Rough-in | 1/14/2010 | 1/14/2010 | 1/14/2010 | P | FAIL |
Mike Jordan
|
|
|
eric Phone #: ###-####. Needs to provide engineering from truss co. for crushed bottom chord on 2 ply BG truss. Remove soffitt from north and south eaves ti verify the 2 layers of 5/8 type x rock. ok to insul. c/n posted. Also needs to have ESC issues resolved prior to next inspection.
|
BLD-Foundation | 12/18/2009 | 12/21/2009 | 12/21/2009 | A | PASS |
Mike Jordan
|
|
|
Nate Phone #: ###-####. Stem walls ok.
|
BLD-Footing | 12/17/2009 | 12/18/2009 | 12/18/2009 | A | PASS |
Mike Jordan
|
|
|
Nate Phone #: ###-####
|