BLD-Final | 9/1/2010 | 9/2/2010 | 9/2/2010 | A | PASS |
Mike Jordan
|
|
|
Brett
|
DOC - Permit Finaled | 9/2/2010 | 9/2/2010 | 9/2/2010 | P | PASS |
Mike Jordan
|
|
|
Certificate of occupancy was issued.
|
BLD-Energy code compliance | 8/5/2010 | 8/5/2010 | 8/5/2010 | P | PASS |
Mike Jordan
|
|
|
ray Phone #: ###-####
|
BLD-Framing/Rough-in | 8/5/2010 | 8/5/2010 | 8/5/2010 | P | PASS |
Mike Jordan
|
|
|
ray Phone #: ###-####. All framing issues have been resolved.
|
BLD-Framing/Rough-in | 8/3/2010 | 8/4/2010 | 8/4/2010 | A | FAIL |
Mike Jordan
|
|
|
Ray Phone #: ###-####. Complete lateral bracing on A3 truss, Provide 9 inch on center nailing on B3 bottom chord, Install 2 layers of 5/8 type x rock on east and west soffitts, repair top plates at interior bathrrom wall at 2nd floor and fireblock. ok to insulate. Correction notice was posted.
|
BLD-Foundation | 7/13/2010 | 7/14/2010 | 7/14/2010 | A | PASS |
Jim Storey
|
|
|
Manuel Phone #: ###-####
|
BLD-Footing | 7/13/2010 | 7/13/2010 | 7/13/2010 | P | PASS |
Mike Jordan
|
|
|
Phone #: ###-####
|