Permit Information
Permit NumberBLD10-02410
StatusFinaled
Name ENVISION 360 INC
Site Address 2110 W BRITTANY LN
Project NameLANCASTER TERRACE
Customer Number 
ePlanReviewNo
Description
(2110 LANCASTER TERRACE APARTMENTS) **6-29-2011 PLAN MODIFICATION TO INCLUDE: STRENGTHEN FLOOR JOISTS IN SPECIFIC AREAS PER PLANS AND ENGINEERING THAT WILL RECEIVE ADDITIONAL LOADING FROM THE ADDITION OF GYPCRETE; ENCLOSE EXISTING EXTERIOR MEANS OF EGRESS STAIRWAYS PER THE APPROVED PLANS, ALL RED-LINING, ENGINEERING, ATTACHED PLAN REVIEW REPORT, AND THE STRUCTURAL INSPECTORS FINAL APPROVAL** To repair an existing Fire damaged, 8,277 square foot, three story, wood framed, six unit apartment building. The fire damaged units were 100, 200, and 300. Work to include: repair/replace various roof areas including decking, and class A shingles; completely replace exterior front entry deck, stair system, handrails, guards, balusters, deck support posts, and floor joist decking; repair walkways; repair/replace air conditioning openings; replace interior wall and ceiling drywall (min. 5/8" Type X G.W.B.), One-hour dwelling unit separation is required in areas of drywall replacement; replace designated windows, floor coverings, paint, cabinets, electrical, plumbing and mechanical as required; replace exterior siding as needed, exterior paint, and miscellaneous finish work. Roof truss, floor joist, entry deck/balconies, and framing repairs as per structural engineer's evaluation and attached report. All electrical, plumbing and mechanical work per applicable codes and require separate permits. All exterior wood surfaces shall be protected from the elements with a protective treatment and comply with the 2006 IBC for weather protection. The installation of smoke detectors are required and are to be installed in all sleeping rooms and access hallways providing access to sleeping rooms. All construction shall be per chapter 39 of the 2006 IBC. All work per the approved plans, attached Engineering, other reviewing departments approvals, the structural inspectors approval, and the plan review report. NOTE: Retaining walls are not part of this permit and require separate permits. A life safety inspection shall be completed prior to issuance of a new certificate of occupancy. **SRZ** (previous expired permits Bld06-03328 and Bld09-01897) ESC09-00676
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference4/11/20124/13/20124/16/2012APASS
DetailsTony Young
Chad Phone #: ###-####,, final ok
DOC - Permit Finaled4/16/20124/16/20124/16/2012PPASS
DetailsTony Young
c of c issued
BLD-Final3/23/20123/26/20124/11/2012APASS
DetailsTony Young
Chad Phone #: ###-####,,still need site improvments
BLD-Final3/15/20123/16/20123/28/2012PPASS
DetailsTony Young
Chad Phone #: ###-####
FIRE-Final Inspection3/15/20123/16/20123/16/2012APASS
DetailsForrest France
Fire life safety inspection passed.
BLD-Energy code compliance12/28/201112/30/201112/30/2011ADONE
DetailsTony Young
Chad Phone #: ###-####,,, ok to cover
BLD-Energy code compliance12/27/201112/28/201112/28/2011APART
DetailsTony Young
Chad Phone #: ###-####,,, ok but needs exhuast fans vented to exterior,,, Chad said they are on the way
BLD-Energy code compliance12/23/201112/27/201112/27/2011PNR
DetailsTony Young
Chad Phone #: ###-####,,, need to finish exhaust terminations
BLD-Energy code compliance12/22/201112/23/201112/23/2011PPART
DetailsTony Young
Chad Phone #: ###-####,,, after further review,,, mechanical will need to be revised for fans and dryers and duct out properly,, some areas still ok to cover that are not effected by this
BLD-Energy code compliance12/21/201112/22/201112/22/2011PPART
DetailsTony Young
Chad Phone #: ###-####,,, some units ok
BLD-Energy code compliance12/20/201112/21/201112/21/2011PNR
DetailsTony Young
Chad Phone #: ###-####
BLD-Framing/Rough-in12/20/201112/20/201112/20/2011PPART
DetailsTony Young
Chad Phone #: ###-####,,, verbal corrections,, fireblocking by insulation,,, mech and plm trades approved from prior inspections,, in 2007,, appears ok
BLD-Framing/Rough-in11/29/201111/29/201111/29/2011PNR
DetailsTony Young
Chad Phone #: ###-####,, conf only
BLD-Conference5/23/20115/23/20115/26/2011PPASS
DetailsTony Young
Derek Phone #: ###-####
BLD-Footing4/1/20114/1/20114/4/2011PNR
DetailsTony Young
chad - pouring at 2:30 Phone #: ###-####
BLD-Aging Inspection3/16/20113/16/20113/24/2011 PEND
DetailsTony Young
BLD-Aging Inspection1/14/20111/14/20111/20/2011 PEND
DetailsTony Young