Permit Information
Permit NumberBLD11-00740
StatusFinaled
Name STETSON HOMES INC
Site Address 11418 W GREYLING CT
Project Name 
Customer Number 
ePlanReviewNo
Description
To construct a new 2752s.f. 2-story single family dwelling with 1692s.f. on the main level and an upper level of 1060s.f. that extends about 24" over the 719s.f. 3-car garage. R-1A ok per Sue Cummings. All per the approved plans as marked REScheck and the plan review notes. pep
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/17/20118/17/20118/17/2011APASS
DetailsMike Jordan
rustin please call for access code Phone #: ###-####
DOC - Permit Finaled8/17/20118/17/20118/17/2011PPASS
DetailsMike Jordan
All issues were resolved. A laminate safety film was installed on window that needed to be tempered and meets ANSI Z 97.1. A letter will be scanned into permit docs from Idaho window tinting. Residential certificate of occupancy was issued.
BLD-Final8/12/20118/12/20118/12/2011PFAIL
DetailsMike Jordan
Rustin Phone #: ###-####. Provide blower door results, post enrgy cert., and provide tempered glazing at winow next to back door.
BLD-Energy code compliance6/7/20116/8/20116/8/2011APASS
DetailsMike Jordan
Rustin Phone #: ###-####
BLD-Framing/Rough-in6/6/20116/6/20116/6/2011PPASS
DetailsMike Jordan
Rustin Ray Phone #: ###-####. All issues have been resolved. Ok to insulate.
BLD-Framing/Rough-in6/3/20116/3/20116/3/2011PFAIL
DetailsMike Jordan
rustin Phone #: ###-####. Not all corrections have been made.
BLD-Framing/Rough-in6/2/20116/2/20116/2/2011PFAIL
DetailsMike Jordan
Rusten Phone #: ###-####. Needs mech rough in inspection. Insulation must be incapsulated on all six sides at on walls with unconditioned space on one side, to be completed on framing inspection. Provide tall wall detail. Foam seal around exterior wall at gas pipe penetration behind fireplace. Complete fire blocking at drop ceiling in closet upstairs and were mechanical ducts pass thru. Also needs to foam seal at double 2x6 at ceiling in living room nw end. Replaced the 3 2x6 studs at tall wall above header (by front door) they were cut to short. Replace modified simpson hangars at double LVL in living room. A;lso redlined on plans, operable window in master siute to close to mechanical (fireplace vent). Correction notice was posted. Do not insulate.
BLD-Foundation5/5/20115/6/20115/6/2011APASS
DetailsMike Jordan
ready for inspection around 11:00 - 12:00 Phone #: ###-#### >> Inspection requested via web by Ben Sears
BLD-Footing5/5/20115/5/20115/5/2011PPASS
DetailsMike Jordan
ben Phone #: ###-####