Permit Number | BLD12-00584 |
Status | Finaled |
Name |
MICRON TECHNOLOGY INC
|
Site Address |
8000 S FEDERAL WAY
|
Project Name | |
Customer Number | C16501 |
ePlanReview | No |
Description |
Tenant Improvement (Existing): C16501 - B26 - Grid Line 10 & B on 1st floor. Replace 20-minute corridor Fire Rated Double doors with new 20-minute smoke - fire rated doors into the corridor, with smoke detector activated mag hold opens. New corridor doors provide access / egress to a new 8' x 8' vestibule being created between the dirty corridor and clean room area. Access / egress between the vesibule and the clean room are by automatic sliders with break-away capabilities. To add smoke detectors on both sides of doors at corridor to activate hold opens and install a new strobe within the new vestibule. Separate sprinkler system and alarm permits are required before any work can begin on either of these systems, as regulated by the fire department. Sprinkler system was used for allowable area increase. Building data from Micron: Prop Use/Occ Class: F1 Exist Use/Occ Class: F1 Fire spr? Y Area increase? Y Fire Resis Sub? N Story increase? N fire alarm sys? Y floor: 1 exist load: 2 prop load: 2 drs
|