Information based on query as of Friday, June 28, 2024.
Permit Information
Permit NumberBLD12-01135
StatusFinaled
Name WESTMINSTER II
Site Address 11525 W PECONIC CRT
Project Name 
Customer Number 
ePlanReviewNo
Description
Permit for the construction of a new 2,343 sq. ft., one story single family dwelling with 3 bedrooms, 2 1/2 bathrooms, approximately 311 sq. ft. of covered patio/porch and a 638 sq. ft. attached garage per the approved plans, plan review report and any notations. R-1A zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/19/20145/20/20145/20/2014PPASS
DetailsMike Jordan
Charley Cooper Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris
DOC - Permit Finaled5/20/20145/20/20145/20/2014PPASS
DetailsMike Jordan
All issues have been resolved.
BLD-Blower Door Test Results5/20/20145/20/20145/20/2014PDONE
DetailsMike Jordan
3.6
BLD-Final5/15/20145/16/20145/16/2014PFAIL
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris. Provide blower door test results and provide tempered glazing at window in 2nd. master bedroom.
BLD-Final5/14/20145/15/20145/15/2014PNR
DetailsMike Jordan
contact person: Charley Cooper Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris
BLD-Framing/Rough-in4/4/20144/7/20144/7/2014APASS
DetailsTom Arcoraci
Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris dry wall ok
BLD-Energy code compliance3/26/20143/27/20143/27/2014APASS
DetailsTom Arcoraci
Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris
BLD-Framing/Rough-in3/20/20143/21/20143/21/2014AFAIL
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris. Strap LVL beams to stud connection at north wall, also provide additional bearingfor northwest LVL. fireblock concealed space at ceiling next to clost behind shower stall. Provide straps at garage header for portal frame. No bearing for western most T14 truss. Ok to insulate. Correction notice posted.
BLD-Framing/Rough-in3/17/20143/18/20143/17/2014PCANC
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by Lorrie Ferris Inspection cancelled from web by: Lorrie Ferris
BLD-Conference11/28/201211/28/201211/28/2012PFAIL
DetailsMike Jordan
A coorection notice was issued no wall bracing inspection has been done, tyvek and siding has been placed.
BLD-Foundation9/7/20129/12/20129/12/2012PPASS
DetailsMike Jordan
Sebastian Phone #: ###-####
BLD-Footing9/7/20129/11/20129/11/2012PPASS
DetailsMike Jordan
Sebastian Phone #: ###-####
BLD-Conference2/28/20142/28/2014 P 
DetailsMike Jordan
Bracing may be accomplished by gypsum on interior, nailed with 6D coolers at 7" o.c..