Permit for the construction of a new 1,340 sq. ft., three story (first story 228 sq. ft, second story 552 sq. ft., third story 560 sq. ft.) Townhouse with 3 bedrooms, 2 1/2 bathrooms, approximately 90 sq. ft. of covered patio/porch and a 379 sq. ft. attached garage per the approved plans, plan review report and any notations. R-2D zoning and setbacks per planning. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/18/20137/18/20137/18/2013PPASS
DetailsTom Arcoraci
Please call 1/2 hr prior. Thanks Jim Phone #: ###-#### >> Inspection requested via web by James Larkin
DOC - Permit Finaled7/18/20137/18/20137/18/2013PPASS
DetailsTom Arcoraci
FIRE-Final Inspection7/18/20137/18/20137/18/2013PCANC
DetailsTroy Cobbley
please call 1/2 hr prior.
thanks Jim Phone #: ###-#### >> Inspection requested via web by James Larkin Inspection cancelled from web by: James Larkin
BLD-Final7/16/20137/17/20137/17/2013ANR
DetailsTom Arcoraci
Please call 1/2hr prior.
Thanks Jim Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Energy code compliance3/28/20133/28/20133/28/2013PPASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Framing/Rough-in3/28/20133/28/20133/28/2013PPASS
DetailsMike Jordan
Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Energy code compliance3/26/20133/26/20133/26/2013PFAIL
DetailsMike Jordan
Please call 1 hour prior Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Framing/Rough-in3/22/20133/22/20133/22/2013PFAIL
DetailsMike Jordan
please call 1/2 prior Phone #: ###-#### >> Inspection requested via web by James Larkin. Strap 2x6 top plate at laundry room, provide additional 2x at 2ply LVL for stair header south entry, remove osb from laydown parapet and replace with fire treated ply. ok to insulate. Correction notice posted.
BLD-Framing/Rough-in2/18/20132/19/20132/19/2013PNR
DetailsMike Jordan
Please call 1hr prior Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Wall cover1/9/20131/9/20131/9/2013APASS
DetailsMike Jordan
firewall Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Wall cover1/7/20131/7/20131/7/2013APASS
DetailsMike Jordan
firewall construction Phone #: ###-#### >> Inspection requested via web by James Larkin. previous issues have been corrected.
BLD-Wall cover1/4/20131/4/20131/4/2013AFAIL
DetailsMike Jordan
firewall Phone #: ###-#### >> Inspection requested via web by James Larkin. Remove face layer and attach base layer as per aprroved assyembly.
BLD-Wall cover1/3/20131/3/20131/3/2013PPASS
DetailsMike Jordan
Firewall Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Wall cover12/20/201212/20/201212/21/2012PPASS
DetailsMike Jordan
Firewall Construction Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Wall cover12/19/201212/19/201212/19/2012PPASS
DetailsMike Jordan
Firewall Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Wall cover12/19/201212/19/201212/19/2012PPASS
DetailsMike Jordan
Firewall Phone #: ###-#### >> Inspection requested via web by James Larkin
BLD-Wall cover12/19/201212/19/201212/19/2012APASS
DetailsMike Jordan
Firewall Construction Phone #: ###-#### >> Inspection requested via web by James Larkin. 1st. floor, base layer 5/8 type x ok.
BLD-Footing10/4/201210/5/201210/5/2012APASS
DetailsTom Arcoraci
Greg Phone #: ###-####
BLD-Energy code compliance9/25/20129/25/20129/26/2012PPASS
DetailsMike Jordan
steve Phone #: ###-####. rigid foam insulation, interior side of stemwall under slab on grade.
BLD-Foundation9/18/20129/20/20129/20/2012PPASS
DetailsMike Jordan
Phone #: 2085739589 >> Inspection requested via mobile web by Ricardo
BLD-Foundation9/17/20129/19/20129/19/2012PCANC
DetailsMike Jordan
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
BLD-Footing9/18/20129/19/20129/19/2012PPASS
DetailsMike Jordan
Phone #: 2085739589 >> Inspection requested via mobile web by Ricardo
BLD-Footing9/17/20129/18/20129/18/2012PCANC
DetailsMike Jordan
Phone #: 2089410987 >> Inspection requested via mobile web by Bill
BLD-Foundation9/14/20129/18/20129/18/2012PCANC
DetailsMike Jordan
Phone #: 2085739589 >> Inspection requested via mobile web by Ricardo
BLD-Footing9/14/20129/17/20129/17/2012PNR
DetailsMike Jordan
Phone #: 2085739589 >> Inspection requested via mobile web by Ricardo