Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD12-02961
StatusFinaled
Name PRISTINE POOLS AND SPAS
Site Address 12650 W RUNNING BROOK CT
Project Name 
Customer Number 
ePlanReviewNo
Description
To place a new 538s.f. inground swimming pool in the rear yard of an existing single family dwelling and R-1C setbacks approved by Colleen Carroll. This pool shall conform to all safety and precautionary requirements of Appendix chapter "G" of the 2009 IRC. Separate electrical, mechanical and ESC permits are required. All per the approved plans and engineer's documents. pep
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/30/20187/30/20187/30/2018PPASS
DetailsJim Sly
call 20 mins ahead- Marcus Phone #: ###-####
DOC - Permit Finaled7/30/20187/30/20187/30/2018PPASS
DetailsJim Sly
BLD-Final1/22/20181/23/20181/23/2018ANR
DetailsJim Sly
Marcus and he''s the homeowner-he said the pool co did not call in the final after they made the corrections-can you please call him with an approximate meet time Phone #: ###-####

Need to eliminate ability to climb fence from the outside. Told Marcus that he could install a pc of 2 foot x 8 foot 7/16 OSB from intermediate horizontal 2x4 to top horizontal 2x4......thus separation beween horizontals will be more than 45 inches complying with sect. AG 105 # 4 and 5.
BLD-Final5/15/20135/16/20135/16/2013PFAIL
DetailsJim Sly
Ryan Julian Phone #: ###-####
C/N posted....Barrier requirements.
BLD-Other12/17/201212/17/201212/17/2012PPASS
DetailsJim Sly
renn Phone #: ###-####
Rebar OK.