BLD-Final | 10/22/2013 | 10/23/2013 | 10/23/2013 | A | PASS |
Jim Storey
|
|
|
Dan-Please call at least 30 mins prior to insepction Phone #: ###-####
|
DOC - Permit Finaled | 10/23/2013 | 10/23/2013 | 10/23/2013 | P | PASS |
Jim Storey
|
|
|
|
BLD-Framing/Rough-in | 8/27/2013 | 8/28/2013 | 8/28/2013 | A | PASS |
Tony Young
|
|
|
dan Phone #: ###-####,, porches
|
BLD-Conference | 8/6/2013 | 8/7/2013 | 8/7/2013 | A | PASS |
Tony Young
|
|
|
footings for patio extension Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson
|
BLD-Framing/Rough-in | 8/1/2013 | 8/2/2013 | 8/2/2013 | A | PART |
Tony Young
|
|
|
Framing final before insulation is put in walls. Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson,, needs straps on short top plate overlaps,, nail all holes in hangers,, add cripple above front door,, finish door framing on interior doors,, support/shim floor joists,, shim headers/trimmers,, ok to insulate
|
BLD-Conference | 4/30/2013 | 4/30/2013 | 5/8/2013 | P | PART |
Tony Young
|
|
|
Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson,, frame ?s
|
BLD-Conference | 4/22/2013 | 4/23/2013 | 5/1/2013 | A | PEND |
Tony Young
|
|
|
Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson
|
BLD-Framing/Rough-in | 4/19/2013 | 4/22/2013 | 4/22/2013 | A | NR |
Tony Young
|
|
|
Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson,, ok to cover exterior,, will need to retrofit a hold down.. recomend some floor to floor straps as well... need to nail or bolt sole plate down
|
BLD-Foundation | 2/19/2013 | 2/19/2013 | 2/20/2013 | P | PART |
Tony Young
|
|
|
Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson
|
BLD-Foundation | 2/18/2013 | 2/19/2013 | 2/19/2013 | A | PART |
Tony Young
|
|
|
Phone #: ###-#### >> Inspection requested via web by Lawrence Johnson,, ok to pour after doweling into existing foundation
|
BLD-Footing | 2/11/2013 | 2/12/2013 | 2/12/2013 | A | PART |
Tony Young
|
|
|
Pouring at 11 - buzz Phone #: ###-####,,
|