BLD-Final | 5/10/2013 | 5/10/2013 | 5/10/2013 | P | PASS |
Mike Jordan
|
|
|
MIke Phone #: ###-####. Blower door test done and results posted.
|
DOC - Permit Finaled | 5/10/2013 | 5/10/2013 | 5/10/2013 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 5/8/2013 | 5/9/2013 | 5/9/2013 | A | FAIL |
Mike Jordan
|
|
|
mike Phone #: ###-####. Handrail installed. Still no blower door test results or 3rd party airseal report.
|
BLD-Final | 5/3/2013 | 5/6/2013 | 5/6/2013 | A | FAIL |
Mike Jordan
|
|
|
Mike Phone #: ###-####. need blower door and handrail in garage. Correction notice posted.
|
BLD-Energy code compliance | 3/15/2013 | 3/18/2013 | 3/18/2013 | A | PASS |
Mike Jordan
|
|
|
Mike Phone #: ###-####
|
BLD-Framing/Rough-in | 3/15/2013 | 3/18/2013 | 3/18/2013 | A | PASS |
Mike Jordan
|
|
|
Mike Phone #: ###-####
|
BLD-Framing/Rough-in | 3/12/2013 | 3/12/2013 | 3/12/2013 | P | FAIL |
Mike Jordan
|
|
|
Mike Phone #: ###-####. Provide additional lateral bracing (purlin) on top chord of trusses at north and south overbuilds were roof sheathing has been stopped. ok to insulate.
|
BLD-Wall Bracing | 2/27/2013 | 2/28/2013 | 2/28/2013 | A | PASS |
Mike Jordan
|
|
|
mike Phone #: ###-####
|
BLD-Foundation | 2/13/2013 | 2/15/2013 | 2/15/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 2/13/2013 | 2/14/2013 | 2/14/2013 | P | PART |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 2/13/2013 | 2/14/2013 | 2/13/2013 | A | CANC |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron Inspection cancelled via mobile web on Wednesday, February 13, 2013.
|
BLD-Foundation | 2/11/2013 | 2/13/2013 | 2/13/2013 | A | NR |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 2/11/2013 | 2/12/2013 | 2/12/2013 | P | FAIL |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron. Need to have property pins located or reshot. Excavation needs to be deeper on ne and se ends.
|
BLD-Foundation | 2/8/2013 | 2/12/2013 | 2/11/2013 | A | CANC |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron Inspection cancelled via mobile web on Monday, February 11, 2013.
|
BLD-Footing | 2/8/2013 | 2/11/2013 | 2/11/2013 | P | NR |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|