BLD-Final | 8/28/2013 | 8/29/2013 | 8/29/2013 | A | PASS |
Mike Jordan
|
|
|
Please call 1/2 hr prior Phone #: ###-#### >> Inspection requested via web by James Larkin
|
DOC - Permit Finaled | 8/29/2013 | 8/29/2013 | 8/29/2013 | P | PASS |
Mike Jordan
|
|
|
|
BLD-Wall cover | 6/26/2013 | 6/26/2013 | 6/26/2013 | A | PASS |
Mike Jordan
|
|
|
Interior firewall Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Energy code compliance | 6/25/2013 | 6/25/2013 | 6/25/2013 | A | PASS |
Jim Sly
|
|
|
Please call 1/2 hr prior.
Thanks jim Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Energy code compliance | 6/24/2013 | 6/24/2013 | 6/24/2013 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Framing/Rough-in | 6/24/2013 | 6/24/2013 | 6/24/2013 | P | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin. All framing issues not yet resolved.
|
BLD-Energy code compliance | 6/18/2013 | 6/18/2013 | 6/18/2013 | A | NR |
Dave Hannah
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Framing/Rough-in | 6/14/2013 | 6/14/2013 | 6/14/2013 | A | FAIL |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin. Fire caulk all penetrations at 1 hr. wall. Box out electrical ground in garage with 5/8 ype x rock. Remove non rated low voltage box from 1hr wall. Fireblock concealed area at stairs (ceiling level.) Insall SDS screws in 2ply girder in garage. Correction notice posted. Ok to insulate.
|
BLD-Wall Bracing | 5/21/2013 | 5/22/2013 | 5/22/2013 | A | PART |
Mike Jordan
|
|
|
Firewall Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Wall Bracing | 5/16/2013 | 5/16/2013 | 5/16/2013 | P | PART |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin2nd floor.
|
BLD-Wall Bracing | 5/8/2013 | 5/8/2013 | 5/8/2013 | P | NR |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Conference | 5/7/2013 | 5/7/2013 | 5/7/2013 | A | PASS |
Tom Arcoraci
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin wip ok
|
BLD-Wall Bracing | 5/3/2013 | 5/3/2013 | 5/3/2013 | P | NR |
Mike Jordan
|
|
|
|
BLD-Wall Bracing | 5/2/2013 | 5/2/2013 | 5/2/2013 | P | CANC |
Mike Jordan
|
|
|
Phone #: ###-#### >> Inspection requested via web by James Larkin
|
BLD-Footing | 4/29/2013 | 4/30/2013 | 4/30/2013 | A | PASS |
Mike Jordan
|
|
|
Greg Phone #: ###-####
|
BLD-Energy code compliance | 4/23/2013 | 4/24/2013 | 4/24/2013 | A | PASS |
Mike Jordan
|
|
|
Greg Phone #: ###-####. Rigid foam insulation, interior side under slab on grade.
|
BLD-Foundation | 4/12/2013 | 4/16/2013 | 4/16/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|
BLD-Footing | 4/12/2013 | 4/15/2013 | 4/15/2013 | P | PASS |
Mike Jordan
|
|
|
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
|