BLD-Final | 4/24/2014 | 4/25/2014 | 4/25/2014 | A | PASS |
Mike Jordan
|
|
|
Cameron Phone #: ###-####
|
DOC - Permit Finaled | 4/25/2014 | 4/25/2014 | 4/25/2014 | P | PASS |
Mike Jordan
|
|
|
blower door done and posted.
|
BLD-Blower Door Test Results | 4/25/2014 | 4/25/2014 | 4/25/2014 | A | DONE |
Mike Jordan
|
|
|
4.7
|
BLD-Final | 4/18/2014 | 4/21/2014 | 4/21/2014 | A | FAIL |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Needs to provide blower door test result or the 3rd. party inspection report and post.
|
BLD-Framing/Rough-in | 12/18/2013 | 12/20/2013 | 12/20/2013 | A | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Energy code compliance | 12/20/2013 | 12/20/2013 | 12/20/2013 | A | PASS |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Framing/Rough-in | 12/18/2013 | 12/18/2013 | 12/18/2013 | P | FAIL |
Mike Jordan
|
|
|
Cameron Phone #: ###-####. Nail 2ply common girder as per truss engineering and provide additional stud at north bearing. Nail 2ply hip girder as per truss engineering. Complete lateral bracing on A1, A2, A5, AAH3, AAH4, AH3, AH8, BH6 and CH2 trusses. Strap double top plate splice at interior wall before radius. Block and nail off interior wall brace panel. Provide aditional nailing on 2x6 to LVL for patio or strap. Ok to insulate. Correction notice posted.
|
BLD-Other | 12/11/2013 | 12/12/2013 | 12/12/2013 | A | CANC |
Mike Jordan
|
|
|
cameron - shear inspection Phone #: ###-####
|
BLD-Wall Bracing | 12/12/2013 | 12/12/2013 | 12/12/2013 | A | PASS |
Mike Jordan
|
|
|
cameron - shear inspection Phone #: ###-####
|
BLD-Wall Bracing | 12/9/2013 | 12/10/2013 | 12/10/2013 | P | FAIL |
Mike Jordan
|
|
|
cameron Phone #: ###-####. Install all missing blocking and restaple all lacking and missed areas.
|
BLD-Wall Bracing | 12/6/2013 | 12/9/2013 | 12/9/2013 | P | CANC |
Mike Jordan
|
|
|
cameron Phone #: ###-####
|
BLD-Foundation | 11/8/2013 | 11/12/2013 | 11/12/2013 | A | PASS |
Mike Jordan
|
|
|
bill Phone #: ###-####
|
BLD-Footing | 11/6/2013 | 11/7/2013 | 11/7/2013 | A | PART |
Mike Jordan
|
|
|
Cameron Phone #: ###-####
|