BLD-Final | 4/9/2015 | 4/9/2015 | 4/9/2015 | P | PASS |
Mike Jordan
|
|
|
Dave Phone #: ###-####
|
BLD-Aging Inspection | 3/30/2015 | 3/30/2015 | 3/30/2015 | | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 11/19/2014 | 11/19/2014 | 11/19/2014 | P | PART |
Mike Jordan
|
|
|
Tyler Phone #: ###-####. ok for temp occ. Will be ok for perm occ. once zoning and public works signs perm.
|
BLD-Final | 11/10/2014 | 11/12/2014 | 11/12/2014 | P | FAIL |
Mike Jordan
|
|
|
Tyler Phone #: ###-####. provide the rquired 5/8 type x sheet rock in fire riser room and firestop all penetrations.
|
FIRE-Final Inspection | 11/10/2014 | 11/12/2014 | 11/12/2014 | A | PASS |
Troy Cobbley
|
|
|
life safety passed
|
BLD-Energy code compliance | 9/15/2014 | 9/16/2014 | 9/16/2014 | A | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####
|
BLD-Framing/Rough-in | 9/15/2014 | 9/16/2014 | 9/16/2014 | A | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####
|
BLD-Framing/Rough-in | 9/15/2014 | 9/15/2014 | 9/15/2014 | P | FAIL |
Mike Jordan
|
|
|
Richard Phone #: ###-####. All corrections not made. Still needs to repair draft stops and instaal fireblocking at fur downs.
|
BLD-Framing/Rough-in | 9/11/2014 | 9/12/2014 | 9/12/2014 | P | FAIL |
Mike Jordan
|
|
|
Richard Phone #: ###-####. Repair, and complete draft stop in attic areas. Provide h2.5 at interio bearing wall to trusses, fireblock all furdowns, seal all penetrations thru draft stop.
|
BLD-Wall Bracing | 8/14/2014 | 8/14/2014 | 8/14/2014 | P | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####. Exterior floor to floor straps ok.
|
BLD-Wall Bracing | 8/12/2014 | 8/12/2014 | 8/12/2014 | P | PASS |
Phil Shearer
|
|
|
richard Phone #: ###-####
|
BLD-Wall Bracing | 8/1/2014 | 8/1/2014 | 8/1/2014 | P | PASS |
Jim Storey
|
|
|
Richard Phone #: ###-####
|
BLD-Wall Bracing | 7/31/2014 | 7/31/2014 | 7/31/2014 | P | PASS |
Phil Shearer
|
|
|
Richard Phone #: ###-#### All exterior shear walls ok
|
BLD-Wall Bracing | 7/30/2014 | 7/30/2014 | 7/30/2014 | P | PASS |
Phil Shearer
|
|
|
Richard Phone #: ###-#### 2nd floor exterior shear walls ok
|
BLD-Wall Bracing | 7/24/2014 | 7/25/2014 | 7/25/2014 | A | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####. Exterior shear walls, 1st. floor ok.
|
BLD-Wall Bracing | 7/21/2014 | 7/21/2014 | 7/21/2014 | P | NR |
Mike Jordan
|
|
|
Ken Phone #: ###-####
|
BLD-Wall Bracing | 7/18/2014 | 7/18/2014 | 7/18/2014 | P | PASS |
Mike Jordan
|
|
|
Ken Phone #: ###-####. Interior shear walls, 1st. floor only.
|
BLD-Foundation | 7/7/2014 | 7/7/2014 | 7/7/2014 | P | CANC |
Mike Jordan
|
|
|
Ashely-Foundation energy Phone #: ###-####. rigid insulation, interior side of stemwall under slab on grade.
|
BLD-Foundation | 6/30/2014 | 7/1/2014 | 7/1/2014 | P | PASS |
Mike Jordan
|
|
|
Manual Phone #: ###-####
|
BLD-Footing | 6/27/2014 | 6/30/2014 | 6/30/2014 | P | PASS |
Mike Jordan
|
|
|
Manuel Phone #: ###-####
|