BLD-Final | 4/9/2015 | 4/9/2015 | 4/9/2015 | P | PASS |
Mike Jordan
|
|
|
Dave Phone #: ###-####
|
BLD-Aging Inspection | 1/27/2015 | 1/27/2015 | 1/27/2015 | | PASS |
Mike Jordan
|
|
|
|
BLD-Final | 10/21/2014 | 10/22/2014 | 10/22/2014 | A | PART |
Mike Jordan
|
|
|
Danny Phone #: ###-####. ok for temp occ. Ok for temp occ. provide additional layer of 5/8 type x on lid and complete fire caulking in riser room.
|
FIRE-Final Inspection | 10/20/2014 | 10/21/2014 | 10/21/2014 | A | PASS |
Craig D. Hanson
|
|
|
|
BLD-Energy code compliance | 9/4/2014 | 9/5/2014 | 9/5/2014 | A | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####
|
BLD-Framing/Rough-in | 9/4/2014 | 9/5/2014 | 9/5/2014 | A | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####
|
BLD-Framing/Rough-in | 9/4/2014 | 9/4/2014 | 9/4/2014 | P | NR |
Mike Jordan
|
|
|
|
BLD-Framing/Rough-in | 9/3/2014 | 9/4/2014 | 9/4/2014 | A | FAIL |
Mike Jordan
|
|
|
Richard Phone #: ###-####. Seal all penetrations in draft stop, strap top plate 1st.floor, in b unit at pvc pipes. Provide the correct headers in the a units by stairs, remove the rim board and reattach floor joist, provide roll blocking in a units at trusses above main entry doors. Provide the 4x4 posts with required connectors at base and top of post in A units.
|
BLD-Wall Bracing | 8/15/2014 | 8/15/2014 | 8/15/2014 | P | PASS |
Mike Jordan
|
|
|
Richard Phone #: ###-####. exterior floor to floor straps ok.
|
BLD-Wall Bracing | 8/14/2014 | 8/14/2014 | 8/14/2014 | P | FAIL |
Mike Jordan
|
|
|
Richard Phone #: ###-####. Exterior floor to floor straps, all not installed.
|
BLD-Wall Bracing | 8/1/2014 | 8/1/2014 | 8/1/2014 | P | PASS |
Jim Storey
|
|
|
Richard-strap Phone #: ###-####
|
BLD-Wall Bracing | 7/24/2014 | 7/24/2014 | 7/24/2014 | P | PASS |
Mike Jordan
|
|
|
2nd fl wall shear - Richard Phone #: ###-####. remainder of exterior walls 2nd floor ok.
|
BLD-Wall Bracing | 7/23/2014 | 7/23/2014 | 7/23/2014 | P | PASS |
Mike Jordan
|
|
|
Richard-shear & strap Phone #: ###-####. !st. floor exterior shear walls ok, 1st. floor interior shear walls ok. 2nd. floor exterior shear walls ok.
|
BLD-Wall Bracing | 7/21/2014 | 7/22/2014 | 7/22/2014 | A | PASS |
Mike Jordan
|
|
|
Ken Scaggs Phone #: ###-####. Interior shear walls 1st. floor ok.
|
BLD-Wall Bracing | 7/21/2014 | 7/21/2014 | 7/21/2014 | P | NR |
Mike Jordan
|
|
|
Ken Phone #: ###-####
|
BLD-Energy code compliance | 6/25/2014 | 6/26/2014 | 6/26/2014 | P | PASS |
Mike Jordan
|
|
|
Ashley Phone #: ###-####. Rigid insulation at stemwaal under slab on grade ok.
|
BLD-Foundation | 6/24/2014 | 6/24/2014 | 6/24/2014 | P | PASS |
Mike Jordan
|
|
|
Manual Phone #: ###-####
|
BLD-Footing | 6/23/2014 | 6/24/2014 | 6/24/2014 | A | PASS |
Mike Jordan
|
|
|
Dave Phone #: ###-####
|