Permit Number | BLD14-01580 |
Status | Finaled |
Name |
BILTMORE COMPANY
|
Site Address |
6677 W COLEHAVEN DR
|
Project Name | Aberdeen Place Sub #2 |
Customer Number | BLD14-01579, BLD14-01580 |
ePlanReview | No |
Description |
L23B2 - 6677 Colehaven - (Bldg 3) To construct a new 3,836 sq. ft., two story, Four unit, apartment building. Each unit has two bedrooms, and two bathrooms. The 1st story units are required to be Type 'B' units. All units share a common path of egress into and through a 1-hour rated exit corridor with 20 minute fire-resistive, listed, labeled, self-closing door assemblies from the dwelling units into the corridor. All construction per the approved plans, attached plan review report, and all other reviewing agencies approvals. One hour fire-partitions and one hour horizontal assemblies are required between dwelling units. This building is required to be fire sprinklered. The fire sprinkler system shall be per NFPA 13R as regulated by the fire department. DRH13-00276 & CUP13-00017 Per Planning and Zoning. **SRZ**
|