Information based on query as of Wednesday, June 19, 2024.
Permit Information
Permit NumberBLD14-01821
StatusFinaled
Name ESI
Site Address 505 E PARKCENTER BLVD
Project NameThe District at Parkcenter
Customer NumberBLD14-01818 FOR DRAWNGS
ePlanReviewYes
Description
(THE DISTRICT AT PARKCENTER - COTTAGE BUILDING A - #3) (12-11-15 PLAN MODIFICATION TO RE-DESIGN THE STRUCTURAL SYSTEM FROM THE FOUNDATION UP. REVISED STRUCTURAL DRAWINGS ARE FILED UNDER BLD14-01821 IN EPLANREVIEW.) (The other drawings are filed under permit BLD14-01818 in ePlanReview) To construct a 10 dwelling unit two story apartment building with each unit having its own garage (i.e. 10 garages). The total floor area of this building is about 14,708 square feet (8,374 square feet 1st story and 6,334 square feet 2nd story). All ground floor units are required to comply as Type B units. Two of those ground floor units within Cottage Building A - #2 are required to comply as Type A units. Work is to include interior nonbearing walls, 1-hr bearing walls, 1-hr roof-ceiling assemblies, 1-hr floor-ceiling assemblies, 1-hr dwelling unit separations, attic insulation, interior doors, exterior windows and doors, insulated exterior walls, “Hardi-board” exterior siding, exterior manufactured stone wainscot, composition roof shingles, common stairways within a 1-hr corridor, private interior stairways, garages, garage overhead doors, millwork, and finishes. Structural work includes concrete footings, concrete stem walls, concrete floor slabs on grade with thickened footings at interior bearing walls, wood floor trusses, wood roof trusses, wood columns, wood beams, and shear walls. Special inspection is required for soils, concrete, and wood. The designs for the roof trusses and floor trusses are deferred submittal items. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13R as regulated by the Fire Department. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/27/20171/30/20171/30/2017PPASS
DetailsJim Storey
cory Phone #: ###-####
FIRE-Final Inspection1/30/20171/30/20171/30/2017APASS
DetailsJim Page
Final life fire safety inspection passed/complete
BLD-Aging Inspection1/2/20171/2/20171/4/2017 NR
DetailsJim Storey
BLD-Aging Inspection10/31/201610/31/201610/31/2016 PASS
DetailsJim Storey
BLD-Final8/30/20168/31/20168/31/2016PPASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Corey Hockersmith
FIRE-Final Inspection8/31/20168/31/20168/31/2016PPASS
DetailsJim Page
Final fire sprinkler inspection complete, final fire sprinkler underground supply inspection complete, final fire alarm inspection complete, fire extinguishers are in place with current inspection tags, final life fire safety inspection passed/complete.
BLD-Conference8/29/20168/30/20168/30/2016APART
DetailsJim Storey
Corey Phone #: ###-#### wip
BLD-Other7/22/20167/25/20167/25/2016APASS
DetailsJim Storey
Inspect fire extinguisher cabinet openings Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Wall cover7/7/20167/8/20167/8/2016APASS
DetailsJim Storey
Plumbing penetrations behind cabinet locations Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Ceiling Grid Inspection6/6/20166/7/20166/7/2016APASS
DetailsJim Storey
Bathroom ceiling fur downs Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Wall cover5/4/20165/4/20165/4/2016PPASS
DetailsJim Storey
RC ceiling inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Wall cover5/3/20165/4/20165/4/2016ADEFR
DetailsJim Storey
RC ceiling inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith out of time defered to pm
BLD-Framing/Rough-in4/20/20164/21/20164/21/2016PPASS
DetailsJim Storey
Framing inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in4/20/20164/20/20164/20/2016PNR
DetailsJim Storey
Framing Inspection Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Framing/Rough-in4/7/20164/11/20164/11/2016APART
DetailsJim Storey
Framing inspection first and second floor Phone #: ###-#### Inspection requested via web by Corey Hockersmith c/n posted
BLD-Conference3/29/20163/30/20163/30/2016APART
DetailsJim Storey
Access locations into attic and lighting in garage soffit. Phone #: ###-#### Inspection requested via web by Corey Hockersmith accesses to be adressed by arch/ lights ok as discused
BLD-Wall Bracing3/18/20163/21/20163/21/2016PNR
DetailsJim Storey
Exterior wall bracing Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Wall Bracing3/18/20163/18/20163/18/2016PCANC
DetailsJim Storey
Exterior wall bracing Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Other3/8/20163/9/20163/9/2016APASS
DetailsJim Storey
Roof sheathing and nailing Phone #: ###-#### Inspection requested via web by Kevin Honeycutt
BLD-Wall Bracing2/19/20162/19/20162/19/2016APASS
DetailsJim Storey
2nd floor ok
BLD-Conference1/20/20161/21/20161/21/2016PPASS
DetailsJim Storey
Interior sheer walls Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Foundation8/3/20158/4/20158/4/2015APASS
DetailsJim Storey
concrete to be onsite at 1:00pm Phone #: ###-#### Inspection requested via web by Corey Hockersmith
BLD-Footing7/29/20157/30/20157/30/2015APART
DetailsJim Storey
concrete to be onsite 12:30pm Phone #: ###-#### Inspection requested via web by Corey Hockersmith placed w/si