Information based on query as of Wednesday, June 26, 2024.
Permit Information
Permit NumberBLD15-00681
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 2926 S BARNSIDE WAY
Project NameHR 7-39
Customer Number 
ePlanReviewYes
Description
WUI Zone B, Permit for the construction of a new 2869 sq. ft., two story (first story 1941 sq. ft., second story 928 sq. ft.) single family dwelling with 5 bedrooms, 3 bathrooms, approximately 308 sq. ft. of covered patio/porch and a 704 sq. ft. attached garage per the approved plans, Engineering, prescriptive energy code compliance, ACCA report and any notations. SP-01 zoning and setbacks per planning. //leg
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/20/20157/20/20157/20/2015APASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Weston Wagner
DOC - Permit Finaled7/20/20157/20/20157/20/2015PPASS
DetailsPhil Shearer
BLD-Footing7/8/20157/9/20157/9/2015PCANC
DetailsPhil Shearer
Dane Phone #: ###-####
BLD-Energy code compliance5/5/20155/6/20155/6/2015APASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Weston Wagner
BLD-Framing/Rough-in5/4/20155/5/20155/5/2015PPASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Weston Wagner
BLD-Energy code compliance5/4/20155/5/20155/4/2015ACANC
DetailsPhil Shearer
Phone #: ###-#### >> Inspection requested via web by Weston Wagner Inspection cancelled from web by: Weston Wagner
BLD-Framing/Rough-in5/1/20155/4/20155/4/2015AFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Weston Wagner R311.3 Floors and landings at exterior doors.
There shall be a landing or floor on each side of each exterior door. The width of each landing shall not be less than the door served. Every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. Exterior landings shall be permitted to have a slope not to exceed 1/4 unit vertical in 12 units horizontal (2-percent)./ missing hanger nailling/ tee bracing not per engineering
BLD-Framing/Rough-in4/30/20155/1/20155/1/2015AFAIL
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Austin Wagner. Missing truss bracing on A3, need to fix bracing on A6.Headers over front door and garage door are the wrong size. Need to add headers and fix size of headers on the wall left fire place.
BLD-Wall Bracing4/17/20154/20/20154/20/2015PPASS
DetailsPhil Shearer
Phone #: ###-#### Inspection requested via web by Austin Wagner
BLD-Foundation4/1/20154/1/20154/1/2015APASS
DetailsPhil Shearer
Phone #: 2086971241 >> Inspection requested via mobile web by Heron
BLD-Footing3/31/20153/31/20153/31/2015APASS
DetailsPhil Shearer
Phone #: 2086971241 >> Inspection requested via mobile web by Heron