Permit Information
Permit NumberBLD15-01115
StatusFinaled
Name BACH LAND AND DEVELOPMENT LLC
Site Address 7578 W SAXTON DR
Project NameThe Kensington Apartments T
Customer NumberBLD15-01107 IN EPLAN
ePlanReview 
Description
(THE KENSINGTON APARTMENTS - BUILDING T) The drawings are filed under BLD15-01107 in ePlanReview. The NFPA 13-R fire sprinkler system is used for occupancy and for story increase. To construct a 19,682 square foot four story apartment building (5,246 sq. ft. 1st story with two 2.a units and two 2.e units, 5,246 sq. ft. 2nd story with four 2.a units, 5,246 sq. ft. 3rd story with four 2.a units, and 3,944 sq. ft. 4th story with four 1.b units). All ground floor units are required to comply as Type B dwelling units. No elevator is provided in this building. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud bearing walls, wood stud shear walls, fiberglass shingles, fiber-cement board siding, manufactured stone veneer, 1-hr dwelling unit separations, .5-hr minimum fire-resistance-rated corridors with 20 minute smoke- and draft-control doors, exterior exit stairways fire rated like the corridor, steel stairways with concrete treads, interior nonbearing walls, millwork, and finishes. Special Inspection is required for soils and for concrete. The roof truss design is a deferred submittal item. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13-R and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/22/20173/23/20173/23/2017PPASS
DetailsTony Young
Ed Phone #: ###-####
FIRE-Final Inspection3/22/20173/23/20173/23/2017APASS
DetailsJim Page
Final life fire safety inspection passed/complete
BLD-Aging Inspection1/31/20171/31/20172/1/2017 PASS
DetailsTony Young
BLD-Final9/23/20169/26/20169/26/2016APART
DetailsTony Young
ok pending others?
FIRE-Final Inspection9/26/20169/26/20169/26/2016APASS
DetailsJim Page
Final fire sprinkler inspection complete, final fire alarm inspection complete, fire extinguishers are in place, some have current inspection tags, others will be getting tagged by a licensed contractor (will verify current inspection tag during follow up inspection on other builings at jobsite) Knox box is in place, knox caps for FDC/Standpipe are on order and will be installed after received. Final life fire safety inspection for building T passed/complete.
BLD-Final9/22/20169/23/20169/23/2016PPEND
DetailsDave Hannah
Phone #: ###-#### needs fire life saftey needs elec and change locks ada unit
BLD-Footing8/29/20168/30/20168/30/2016APART
DetailsTony Young
Ed Phone #: ###-####,,, tree root footing,, centerpiece,, pend spec insp
BLD-Energy code compliance6/30/20167/1/20167/1/2016APASS
DetailsPhil Shearer
Ed Phone #: ###-####. 2nd and 3rd floor OK for cover
BLD-Energy code compliance6/29/20166/30/20166/30/2016APASS
DetailsJim Sly
Ed// 1st floor Phone #: ###-####
BLD-Framing/Rough-in6/28/20166/29/20166/29/2016APART
DetailsTony Young
Ed/// inspection for the 3rd floor Phone #: ###-####,, 3rd floor ok to rock lids and insulate
BLD-Framing/Rough-in6/27/20166/28/20166/28/2016APART
DetailsTony Young
Ed Phone #: ###-####,, 1st and 2nd floor ceilings ok to cover,, also ok to insulate walls on same
BLD-Energy code compliance5/27/20166/1/20166/1/2016APART
DetailsTony Young
Ed// 1st floor Phone #: ###-####,, 1st floor ok
BLD-Energy code compliance5/26/20165/27/20165/27/2016APEND
DetailsTony Young
Ed// 4th floor Phone #: ###-####,, pending fire sprinkler pass
BLD-Energy code compliance5/25/20165/26/20165/26/2016APART
DetailsTony Young
Ed// 4th floor Phone #: ###-####,, seal pack ok,, frame ok,, need sprinkler full sign off
BLD-Framing/Rough-in5/20/20165/23/20165/23/2016APART
DetailsTony Young
Ed Phone #: ###-####,, interior fur outs for trades ok to insulate
BLD-Framing/Rough-in5/19/20165/20/20165/20/2016ADEFR
DetailsTony Young
Ed Phone #: ###-####,, out of time
BLD-Wall Bracing4/6/20164/6/20164/6/2016PPART
DetailsJim Sly
Ed Phone #: ###-####
Exterior Nailing and strapping.....OK.
BLD-Energy code compliance3/31/20164/1/20164/1/2016APART
DetailsJim Sly
Ed Phone #: ###-####
Plumbing Walls OK 1st floor.
BLD-Wall cover3/30/20163/31/20163/31/2016APART
DetailsJim Sly
Shear // Ed Phone #: ###-####
OSB shear nailing at E. to W. Center wall ( Plumbing wall)....Main floor OK.
BLD-Other3/15/20163/16/20163/16/2016APART
DetailsTony Young
Nail // Adam Phone #: ###-####,, contractor to verify roof nailing
BLD-Footing1/28/20161/29/20161/29/2016APART
DetailsTony Young
Ed Phone #: ###-####
BLD-Footing1/26/20161/27/20161/27/2016APART
DetailsTony Young
Ed Phone #: ###-####,,, special inspection on site