Permit Information
Permit NumberBLD15-04352
StatusFinaled
Name ESI
Site Address 7020 W STATE ST
Project NameRite Aid
Customer Number 
ePlanReviewYes
Description
(RITE AID) The current locking conditions at the main entry vestible a currenly allowed to remain per the attached document as Rite Aid still occupies both spaces. When the adjaent space is occupied by a new tenant at the vestibule doors will be require to be modified and hardware installed so the doors will be openable from the egress side without the use of a key. Remodel to reduce the size of the tenant space by 19,700 sq. ft. from 40,031 sq. ft. for a new total area of 20,242 sq. ft. per approved plans. Work to include removal of existing shelving and wall steel, check stands, photo counter, and portion of storefront glazing system, install new demising wall and install new shelving, coolers, check stands and related finishes. An additional permit is required to occupy the remaining space. This is a fully fire sprinklered building for area increase. Any alterations to the sprinkler system will require a separate permit and shall comply with NFPA 13 as regulated by the fire department. CDM
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final7/7/20167/8/20167/8/2016APASS
DetailsTony Young
phil Phone #: ###-####,, ok now
FIRE-Final Inspection7/7/20167/8/20167/8/2016APASS
DetailsJim Page
Fire sprinkler inspection complete, final life fire safety inspection passed/complete.
BLD-Final7/6/20167/7/20167/7/2016ANR
DetailsTony Young
Phil Phone #: ###-####
FIRE-Final Inspection7/6/20167/7/20167/7/2016ACANC
DetailsJim Page
Inspection request cancelled by point of contact, inspection request will be rescheduled for a later date.
BLD-Final6/2/20166/2/20166/2/2016PNR
DetailsTony Young
Phil Phone #: ###-####,, needs f/l/s 1st,, no inspection
FIRE-Final Inspection6/1/20166/2/20166/2/2016AFAIL
DetailsTroy Cobbley
Need a plan modification for the front entry doors as per Carl and both leafs of the rear exit door need the panic hardware. All other life safety items have been addressed.
BLD-Final6/1/20166/2/20166/2/2016ADEFR
DetailsTony Young
Phil Phone #: ###-####,, needs f/l/s 1st
BLD-Final3/14/20163/15/20163/15/2016ANR
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Ron Hack,, needs fire 1st
FIRE-Final Inspection3/14/20163/15/20163/15/2016AFAIL
DetailsTroy Cobbley
Provide annual inspection for the fire extinguishers, repair all exit signs and emergency lights, provide emergency lighting at the rear doors, the "Push to Exit" function needs to work on the front exit doors (door schedule calls for panic), provide panic and remove all dead bolts from the rear door.
BLD-Final3/11/20163/14/20163/15/2016PPEND
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Ron Hack
BLD-Framing/Rough-in2/26/20162/26/20162/27/2016PPASS
DetailsTony Young
Partial - John Phone #: ###-####
BLD-Wall cover2/18/20162/18/20162/18/2016PPASS
DetailsTony Young
Phone #: ###-####,, front demising wall ok
BLD-Framing/Rough-in1/29/20161/29/20161/29/2016PPART
DetailsTony Young
Phone #: ###-####,, center area of the demising wall ok,, no trades,, ok to keep working at nights
BLD-Framing/Rough-in1/28/20161/28/20161/28/2016PPART
DetailsTony Young
john Phone #: ###-####,, new pharacy room ok pending electrical rough pass