Permit Information
Permit NumberBLD16-00718
StatusFinaled
Name ANDERSEN CONSTRUCTION CO
Site Address 1109 W MAIN ST Unit: 100
Project NameOwyhee Tavern
Customer Number 
ePlanReviewYes
Description
(OWYHEE TAVERN – OWYHEE PLACE - 1ST STORY – EAST END OF HISTORIC PORTION) The fire sprinkler system is used for building area, height, and story increase. To prepare an existing 5,067 square foot area within an existing building for occupancy as a bar and as a restaurant. The lower level has a floor area of about 1,950 square feet and the upper level has a floor area of about 3,117 square feet. Work is to include interior nonbearing walls, suspended gypsum board ceilings and soffits, a suspended ceiling baffle (wood fins) system, dining booths, a bar, barn style sliding doors, a new interior stairway, a new steel exterior exit stairway, tables and chairs, and interior finishes. Special Inspection is required for welding and for post installed anchors in concrete and/or masonry (i.e. expansion anchors, Titen screws, epoxy anchors, etc.). Directional signage to the entrances that are accessible to the disabled shall be provided. An interior wheelchair lift for the disabled to provide a vertical accessible route between the bar level and the restaurant level will be provided. This restaurant will use the kitchen approved under permit BLD14-00414. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/3/201610/4/201610/4/2016APASS
DetailsDave Hannah
Pete Phone #: ###-####
BLD-Final9/21/20169/22/20169/26/2016PPEND
DetailsDave Hannah
Pete Phone #: ###-#### ok for temp
FIRE-Final Inspection9/23/20169/26/20169/26/2016APASS
DetailsJim Page
Final fire sprinkler inspection complete, final fire alarm inspection complete, final commercial hood fire suppression system inspection complete (Hood suppression modifications under FIR16-00592, permit is not attached to project), fire extinguishers are in place with current inspection tags, inspection tags will expire in November 2016. Final life fire safety inspection passed/complete.
BLD-Final9/23/20169/23/20169/23/2016APART
DetailsDave Hannah
Pete Phone #: ###-#### ok for temp occ
BLD-Framing/Rough-in6/29/20166/30/20166/30/2016PPASS
DetailsDave Hannah
Pete Phone #: ###-####