Permit Information
Permit NumberBLD16-01549
StatusFinaled
Name SHOE SHOW INC
Site Address 350 N MILWAUKEE ST Unit: 2002
Project NameBTS #2002
Customer Number 
ePlanReviewYes
Description
(SHOE DEPT. ENCORE) Boise Town Square Mall #2002. Permit is to remodel an existing 7,972 sq. ft. tenant space. Approval is contingent upon adhering to the approved plans on file. Scope of work includes: construction of new select interior nonbearing walls to create stock room area, rear exit alcove, front gate columns, and an ADA accessible restroom, a new Hi/Lo ADA compliant drinking fountain, a new mop sink, new accessible sales counter, new lighting, electrical work, plumbing work, mechanical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. Note: special inspection required and some of the rough in plumbing work done under BLD16-00523 for new restroom. This building is fully fire sprinklered for area increase any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final10/20/201610/21/201610/21/2016PPASS
DetailsMike Jordan
Kevin Phone #: ###-####.
ok for perm occ.
FIRE-Final Inspection10/20/201610/20/201610/20/2016APASS
DetailsTroy Cobbley
Life safety passed. I discussed with the general contractor about the racks, including the vertical and horizontal portions can not be over 8'. He was going to have the racks modified prior to a building inspection.
FIRE-Final Inspection10/13/201610/14/201610/14/2016PFAIL
DetailsTroy Cobbley
The project is not ready for a final yet. Need doors and hardware and fire extinguishers. Exit signs and emergency lights tested ok. Smoke evac tested ok. I spoke to the contractor about the racking over 8'.
FIRE-Alarm Testing10/13/201610/14/201610/14/2016ADONE
DetailsTroy Cobbley
The smoke evac system testing passed.
BLD-Framing/Rough-in10/2/201610/3/201610/3/2016PPASS
DetailsMike Jordan
Call prior to going Phone #: 8035438600 >> Inspection requested via mobile web by Kevin Beachum. torefront framing ok. Also noted that cloud and air jhandler are now supported from top chords.
BLD-Framing/Rough-in9/13/20169/13/20169/13/2016PPART
DetailsMike Jordan
Call prior to going Phone #: 8035438600 >> Inspection requested via mobile web by Kevin. INterior steel stud framed walls, columns and hardlids ok. Noted that a racking permit is required. Also noted that cloud and air handling unit must be supported from the top chord or provide engineering.
BLD-Framing/Rough-in9/12/20169/12/20169/12/2016PNR
DetailsMike Jordan
Call prior to going Phone #: 8035438600 >> Inspection requested via mobile web by Kevin