Permit Information
Permit NumberBLD16-02033
StatusFinaled
Name BERMENSOLO CONSTRUCTION
Site Address 12400 W MCMILLAN RD
Project NameCentennial High School - Mod 3
Customer NumberBLD16-02031, 2032, 2034
ePlanReviewNo
Description
(CENTENNIAL HIGH SCHOOL – MODULAR CLASSROOM BUILDING #3) (CUP16-00032) This modular building does not have a fire sprinkler system. To relocate a 1,733 square foot modular classroom building from Lake Hazel Middle School (Ada County) to Centennial High School (City of Boise). This modular classroom building will replace an existing modular classroom building that will be relocated off-site for repairs. The finished floor of this building shall be located no more than 30 inches above grade. Work is to include masonry block footing pads, masonry block piers, adjustable jack stands, tie down straps, helix soil anchors, cement board skirting, crawlspace vents, 4 feet high FRP interior wall finish, aluminum exterior ramps, aluminum exterior landings at doors, and exterior concrete sidewalks at grade. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final8/26/20168/26/20168/26/2016PPASS
DetailsJim Sly
Tom Phone #: ###-####
OK for Perm Occ.
FIRE-Final Inspection8/26/20168/26/20168/26/2016PPASS
DetailsTroy Cobbley
life safety passed
BLD-Final8/23/20168/23/20168/23/2016PFAIL
DetailsPhil Shearer
Tom-after 3:00 if possible Phone #: ###-####. Door knobs need to be lever style.
BLD-Final8/22/20168/23/20168/23/2016ADEFR
DetailsPhil Shearer
Tom-after 3:00 if possible Phone #: ###-####
BLD-Final8/19/20168/22/20168/22/2016PNR
DetailsPhil Shearer
Tom Phone #: ###-####
FIRE-Final Inspection8/19/20168/22/20168/22/2016AFAIL
DetailsJim Page
Modular classroom builing did not have fire extinguisher at time of inspection. classroom needs to have fire extinguisher installed. Southeast exit did not have any door hardware installed, this exit is designated as an emergency exit, panic hardware is on site but needs to be installed before next inspection.
BLD-Final8/18/20168/19/20168/20/2016PNR
DetailsJim Sly
Tom Phone #: ###-####
Need Fire alarm and fire life safety.
BLD-Framing/Rough-in7/26/20167/27/20167/27/2016APASS
DetailsJim Sly
Tom Phone #: ###-####