Permit Information
Permit NumberBLD16-02416
StatusFinaled
Name TRILOGY DEVELOPMENT INC
Site Address 8605 W POCONO ST
Project NameSilverCloud Apartments
Customer NumberBLD16-02408 - BLD16-02418
ePlanReview 
Description
(SILVERCLOUD APARTMENTS – BUILDING #4-3 – 4 APARTMENTS – TYPES B2, B1, B1, B2) (DRH16-00080) (PUD16-00003) (11 PERMITS ARE FILED UNDER BLD16-02408 IN EPLANREVIEW) The NFPA 13R fire sprinkler system is used for occupancy. To construct a 2 story apartment building having 4 side-by-side 2 story dwelling units. The dwelling units do not comply as townhomes as defined by the Boise City Code because there are no property lines between them and because the utilities are not separate. This building has a total floor area of about 7,858 square feet (4,383 square feet 1st story and 3,475 square feet 2nd story). Each dwelling unit has 2 stories. None of the dwelling units are required to comply as Type B dwelling units. Work is to include concrete footings, concrete foundations, concrete slabs on grade, wood stud exterior walls, exterior siding, shear walls, wood joist 2nd story floors, doors, windows, interior stairways, gas fireplaces, wood truss roof, roof coverings, millwork, and finishes. Engineered wood trusses are a deferred submittal item. Special Inspection is required for soils, shear walls, diaphragms, concrete, and post-installed anchors. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13R as regulated by the Fire Department. Separate fire sprinkler permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Aging Inspection1/17/20191/17/20191/25/2019 CANC
DetailsTony Young
BLD-Aging Inspection11/13/201811/13/201811/16/2018 PEND
DetailsTony Young
BLD-Aging Inspection9/11/20189/11/20189/18/2018 PEND
DetailsTony Young
BLD-Aging Inspection7/10/20187/10/20187/12/2018 PEND
DetailsTony Young
BLD-Aging Inspection5/8/20185/8/20185/9/2018 PEND
DetailsTony Young
BLD-Final3/7/20183/8/20183/8/2018APASS
DetailsTony Young
Phone #: ###-#### Inspection requested via web by Mike McHargue/// final ok pending others
BLD-Final1/30/20181/30/20181/30/2018PPASS
DetailsTony Young
Contact: Hunter Gomez Phone #: ###-#### Inspection requested via web by Mike McHargue
FIRE-Final Inspection1/16/20181/17/20181/17/2018APASS
DetailsJim Page
Fire sprinkler inspection complete, fire alarm inspection complee, fire extinguishers will be placed under kitchen sinks after sinks are placed. Final life fire safety nispection complete.
BLD-Wall Bracing10/16/201710/16/201710/17/2017PDONE
DetailsTony Young
Interior Sheer Inspection. Contact Hunter Gomez Phone #: ###-#### Inspection requested via web by Mike McHargue
BLD-Energy code compliance9/27/20179/28/20179/28/2017APASS
DetailsJim Sly
Contact: Hunter Gomez Phone #: ###-#### Inspection requested via web by Mike McHargue
BLD-Energy code compliance9/26/20179/27/20179/27/2017ADEFR
DetailsTony Young
Contact: Hunter Gomez Phone #: ###-#### Inspection requested via web by Mike McHargue
BLD-Framing/Rough-in9/22/20179/22/20179/22/2017PPASS
DetailsTony Young
Early PM if possible....Contact: Hunter Gomez Phone #: ###-#### Inspection requested via web by Mike McHargue,, ok to insulate
BLD-Wall Bracing8/7/20178/8/20178/8/2017APASS
DetailsTony Young
Exterior Sheer....Contact Hunter Gomez Phone #: ###-#### Inspection requested via web by Mike McHargue
BLD-Wall Bracing8/4/20178/4/20178/4/2017AFAIL
DetailsMike Jordan
Exterior Shear Phone #: ###-#### Inspection requested via web by Mike McHargue. Missing fasteners, straps, and overshot.
BLD-Footing5/22/20175/23/20175/23/2017APART
DetailsTony Young
Interior Thickened slab footing. Early AM if possible Phone #: ###-#### Inspection requested via web by Mike McHargue
BLD-Energy code compliance4/3/20174/4/20174/4/2017APASS
DetailsTony Young
Foundation Insulation; mid-morning if possible Phone #: ###-#### Inspection requested via web by Mike McHargue
BLD-Foundation3/31/20173/31/20174/3/2017PPASS
DetailsJim Sly
Manuel Phone #: ###-####
BLD-Footing3/28/20173/28/20173/28/2017PPART
DetailsTony Young
Manuel Phone #: ###-####,, work in progress,, ok