Information based on query as of Wednesday, July 24, 2024.
Permit Information
Permit NumberBLD16-02490
StatusFinaled
Name ST LUKES HEALTH SYSTEM LTD
Site Address 316 W WASHINGTON ST
Project NameLittle Luke's
Customer Number 
ePlanReviewYes
Description
(LITTLE LUKE’S EARLY LEARNING CENTER – DAYCARE) (DRH16-00111 / CUP16-00009) (7-11-17 PLAN MODIFICATION TO ADD ONE TOILET AND TO CHANGE THE HAND WASHING FACILITIES SERVING TOILET ROOMS AND LOCATED INSIDE AND OUTSIDE OF TOILET ROOMS TO FOUR STATION FIXTURES INSTEAD OF TWO OR THREE STATIONS FIXTURES. AT LEAST ONE TOILET IN EACH TOILET ROOM IS REQUIRED TO BE ACCESSIBLE TO THE DISABLED BASED ON DIMENSIONS APPLICABLE TO CHILDREN’S USE. CLEARANCES AT NONACCESSIBLE TOILETS ARE REQUIRED TO COMPLY WITH THE PLUMBING CODE (I.E. 15 INCHES MEASURED FROM THE CENTER OF THE TOILET ON EACH SIDE). DRAFT CURTAINS WILL ALSO BE INSTALLED ABOVE THE CEILING AS REQUIRED BY THE FIRE SPRINKLER HEAD SPECIFICATIONS. CJW) The fire sprinkler system is used for building area increase and for occupancy. To create a 10,119 square foot child care facility (daycare) within an existing 20,100 square foot building. Work is to include 2 restrooms accessible to the disabled based on adult dimensions, 4 restrooms accessible to the disabled based on child dimensions, interior nonbearing walls, suspended acoustical ceilings, interior doors, interior windows, exterior storefront doors and windows, millwork, and finishes. Structural work includes new beams and columns to redirect gravity load transfer. A maximum of 108 children are allowed per the Conditional Use Permit. A separate permit is required to establish a Certificate of Occupancy for the adjacent office tenant space located in the West end of this building. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final4/30/20185/1/20185/1/2018APASS
DetailsDave Hannah
Rick Phone #: ###-#### ok for perm occ
BLD-Aging Inspection4/23/20184/23/20185/1/2018 PASS
DetailsDave Hannah
BLD-Final2/20/20182/20/20182/20/2018PPART
DetailsDave Hannah
TCO - Kelly Phone #: ###-#### ok for tco
FIRE-Final Inspection2/12/20182/13/20182/13/2018APASS
DetailsJim Page
Previously noted items have been addressed. Fire sprinkler inspection for area of work complete, fire alarm inspection for area of work complete, fire extinginguishers are in place with current inspection tags. Final life fire safety inspection for area or work complete.
FIRE-Final Inspection2/6/20182/7/20182/7/2018AFAIL
DetailsJim Page
Provide fire extinguishers in discussed locations. Provide double sided exit signs in discussed locations.
BLD-Ceiling Grid Inspection12/19/201712/19/201712/20/2017PPASS
DetailsDave Hannah
BLD-Wall cover12/18/201712/19/201712/19/2017APASS
DetailsDave Hannah
Kelly Phone #: ###-####
BLD-Framing/Rough-in9/13/20179/14/20179/14/2017APASS
DetailsDave Hannah
Kelly Phone #: ###-####
BLD-Framing/Rough-in8/28/20178/29/20178/30/2017APART
DetailsDave Hannah
Kelly Phone #: ###-####