Information based on query as of Wednesday, June 26, 2024.
Permit Information
Permit NumberBLD16-02639
StatusFinaled
Name JARED RAMEY BUILDING COMPANY LLC
Site Address 10516 W BUSINESSPARK LN
Project NameDishion Enterprises
Customer Number 
ePlanReviewYes
Description
**(DISHION ENTERPRISES)** Permit to finish a new 1,526 sq. ft., office tenant space for occupancy. Note: alternate approval on the property line wall (see small documents attached). Approval is contingent upon adhering to the approved plans on file. Work to include: construction of select interior nonbearing walls to create a (2) offices, an open work area, a reception area, an ADA accessible restroom, a coffee bar room, a conference room, a waiting area, a mechanical closet and a janitor’s closet, new millwork, new interior concrete slab, new gyp ceiling, new light fixtures, new plumbing work, new electrical work, new mechanical work and interior finishes to be in compliance with Ch. 8 of the 2012 IBC. Note: Shell permit under BLD06-02310. This building is not Fire Sprinklered **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/9/20171/10/20171/10/2017PPASS
DetailsMike Jordan
Call for access // Jared Phone #: ###-####. All issues were resolved. Ok for perm. occ.
BLD-Final1/4/20171/5/20171/5/2017PFAIL
DetailsMike Jordan
jared Phone #: ###-####. Provide the tactile ADA sign at restroom. Lav in restroom exceeds the 34 inch max allowed height. Counter top in wating area/reception excedds the max allowed 34 inch max height.
FIRE-Final Inspection1/4/20171/5/20171/5/2017APASS
DetailsTroy Cobbley
Life safety passed
FIRE-Final Inspection12/29/201612/30/201612/30/2016AFAIL
DetailsTroy Cobbley
Provide correct sticker at the door, provide fire extinguisher as discussed and provide address as discussed
BLD-Framing/Rough-in11/7/201611/7/201611/7/2016PPART
DetailsMike Jordan
Jared Phone #: ###-####. Framing ok. This tenant side of the 2 layers of 5/8 type x rock has been completed. As per the alternate detail, all ternat sides need to be completed. Spoke with Jared and noted to him per alternate detail and emails, Jared will need to contact other owner on allowing him to provide the 5/8type x on there roof deck. If so, "other owners" will need to submit a plan mod on there tenant improvement portions.
BLD-Energy code compliance11/7/201611/7/201611/7/2016PPASS
DetailsMike Jordan
Call half hour before to meet out to let you in // Jared Phone #: ###-####
BLD-Framing/Rough-in10/18/201610/18/201610/18/2016PPEND
DetailsMike Jordan
Jared Phone #: ###-####. Needs to resubmit to plan review to show 1hr. ceiling assembly, mebrane protection for light fixtures and all mech.
BLD-Energy code compliance10/18/201610/18/201610/18/2016PPASS
DetailsMike Jordan
Jared Phone #: ###-####
BLD-Energy code compliance10/10/201610/11/201610/11/2016ACANC
DetailsMike Jordan
Jared Phone #: ###-####
BLD-Framing/Rough-in10/10/201610/11/201610/11/2016APEND
DetailsMike Jordan
Jared Phone #: ###-####. Shell and core permit expired. Need to final shell and core.
BLD-Framing/Rough-in10/5/201610/5/201610/5/2016PNR
DetailsMike Jordan
Jared Phone #: ###-####. Mech. rough in inspection failed.