Permit Information
Permit NumberBLD17-00091
StatusFinaled
Name ESI
Site Address 1825 W BEACON ST
Project NameIdentity Apartments
Customer Number 
ePlanReviewYes
Description
**Project Management-Ron Hill** (IDENTITY APARTMENTS – NEW PODIUM BUILDING) (DHR 16-00014, CUP15-00088, DHR16-00515, CAR15-00031) The NFPA 13 fire sprinkler system is used for occupancy, story increase, and for building area increase. To construct a 4 story wood framed apartment building (Type V-A construction) having a total of 94 dwelling units (total of 295 bedrooms) over a one story podium (Type I-A construction) having parking, assembly, storage, and office use on the grade level. This building will be 5 stories tall and will have a total floor area of about 143,400 square feet (31,225 square feet 1st story, 28,833 square feet 2nd story, 28,859 square feet 3rd story, 28,856 square feet 4th story, and 25,626 square feet 5th story). All dwelling units are required to comply as Type B dwelling units. At least 2 dwelling units are required to comply as Type A dwelling units. Work is to include concrete footings, concrete foundations, concrete shear walls, horizontal 3-hr fire-resistance-rated podium between the 1st and 2nd stories, an insulated suspended gypsum board ceiling installed below much of the podium, exposed insulation installed to the underside of the rest of the podium where there is no conditioned space below, rigid insulation installed on top of the podium where there is no conditioned space above, slab edge insulation, horizontal 1-hr dwelling unit separations, 1-hr dwelling unit separation walls, enclosed 1-hr fire-resistance-rated corridors, enclosed 2-hr fire-resistance-rated stairway enclosures, enclosed 2-hr fire-resistance-rated mechanical shafts, an enclosed 2-hr fire-resistance-rated trash chute (2-hrs on the 1st story), unenclosed pedestrian bridges, 1-hr wood stud exterior walls, 1-hr wood stud interior bearing walls, 1-hr wood joists floors, 1-hr wood truss roofs, exterior wall finishes, exterior windows, interior and exterior doors, millwork, and interior finishes. Special Inspection is required for soils, concrete (including prestressing tendons), steel (including welding and bolting), and seismic resistance. Wood roof trusses and the structural design for the pre-engineered wood pergola at the 5th story roof deck are deferred submittal items. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection6/4/20186/4/20186/4/2018PPASS
DetailsJim Page
Previously noted items have been repaired, fire sprinkler inspection complete, fire alarm inspection complete, fire extinguishers are in place with current inspection tags, knox box is located by the main entrance. Final life fire safety inspection is complete.

Please call when on site - Evan Phone #: ###-####
BLD-Final6/1/20186/1/20186/1/2018PPASS
DetailsJim Storey
Evan Phone #: ###-#### final ok pending others.
FIRE-Final Inspection5/30/20185/31/20185/31/2018PFAIL
DetailsJim Page
Remaining item that must be completed before life fire safety inspection can be finaled is stairwells (stated in noted on 23MAY2018), stairwells must be 100% completed before life fire safety can be finaled, I spoke with Ron Johnson with Boise Fire and he agrees with staiwells being completed.



Lee Phone #: ###-####
BLD-Other5/30/20185/31/20185/31/2018APASS
DetailsJim Storey
Lee---partial final Phone #: ###-#### bottom of trash shaft ok to cover
FIRE-Conference5/30/20185/30/20185/30/2018PDONE
DetailsJim Page
Fire conference complete.

Lee-- fire proofing--early as possible Phone #: ###-####
FIRE-Final Inspection5/23/20185/23/20185/23/2018PFAIL
DetailsJim Page
Provide "No Roof Access" signage on northwest stairwell. Provide double sided exit signs by th 20 rooms (220, 320, 420 and 520). Fire sprinkler next to exhaust fan in trash room is obstructed. Provide electrical outlet covers that are missing on electrical outlets. Provide an "Emergency Evacuation Plan" for each apartment. Stairwells must be 100% completed before any occupancy. Adjust insulation next to sidewall sprinkler heads to maintain the 4 to 6 inches of vertical clearance that is required. Fire sprinkler heads in level 1 trash room that are painted must be replaced. Ceiling tile that is missing on level 1 must be installed for fire sprinkler heat collection. All fire sprinkler escutcheons need to be in place and installed correctly (no loose or hanging down escutcheons). FIR permits for fire sprinkler and fire alarm must be finaled before life fire safety can be completed.

Lee Scott Phone #: ###-####
BLD-Final5/21/20185/21/20185/21/2018PPART
DetailsJim Storey
Partial final - lee Phone #: ###-####si and engineer sign off ok and archived/ drop ceillings ok
BLD-Wall cover5/18/20185/18/20185/18/2018PPASS
DetailsJim Storey
Lee Phone #: ###-#### doors grouted ok/top of trash shoot and bottom ok to cover// need listing for heater box in trash encloser// pipe collors at podiem ok
BLD-Final5/11/20185/14/20185/14/2018APART
DetailsJim Storey
Request 10am at same time Fire inspector will be there // partial final // Lee Scott Phone #: ###-#### all door above podiem ok forsmoke and latch per listing
FIRE-Final Inspection5/9/20185/11/20185/11/2018AFAIL
DetailsJim Page
Level 1 doors on both stairwells need to have grouting installed for stairwell rating. South emergency exit for parking garage is interfaced with the access control, door cannot be access controled due to the door being the second emergency exit for the parking garage. Emergency exit signs need to be installed in discussed locations. Provide building fire and evacuation plans in each apartment unit per note number 11 of building permit fire code review noted.



Coordinated with Jim for 10am // Evan Phone #: ###-####
BLD-Conference5/9/20185/11/20185/11/2018ACANC
DetailsDave Hannah
Request 10am // Evan Phone #: ###-####
BLD-Final5/10/20185/11/20185/11/2018ACANC
DetailsJim Storey
Lee Scott would like a partial final Phone #: ###-####
BLD-Final5/4/20185/4/20185/4/2018PPART
DetailsJim Storey
Lee Scott Phone #: ###-#### 203 and mop closets
BLD-Final5/3/20185/4/20185/4/2018ADEFR
DetailsJim Storey
Lee Scott Phone #: ###-####
BLD-Other5/2/20185/3/20185/3/2018APASS
DetailsJim Storey
shaft board- lee Phone #: ###-####
BLD-Final4/30/20185/1/20185/1/2018APART
DetailsJim Storey
Area 2 & 3 - Lee Scott Phone #: ###-#### area 2 door closer fail//
BLD-Final4/30/20184/30/20184/30/2018PDEFR
DetailsJim Storey
Area 2 & 3 - Lee Scott Phone #: ###-#### out of time//
BLD-Final4/26/20184/27/20184/27/2018APASS
DetailsJim Storey
area 3 // Lee Scott Phone #: ###-####

area 2 ok need 2 and 3rd door adj one ea. floor// core board ceilling in progress ok
BLD-Wall cover4/19/20184/19/20184/19/2018PPASS
DetailsJim Storey
Lee Phone #: ###-#### 4th floor ceilling patch ok/ storage rooms fire stopping in progress/ shaft patch ok to cover/ firedamper access signs ok
BLD-Final4/16/20184/17/20184/17/2018APASS
DetailsJim Storey
Partial Final - Evan Phone #: ###-####
doors ok area 3 to units/ storage rm firestopping required//4 floor ceilling needs reinsp. spk holes// fire smoke dampers need lables/ list w/ lee
BLD-Energy code compliance3/28/20183/28/20183/28/2018PPASS
DetailsBrandon Shaw
Parking garage ceiling insulation
BLD-Framing/Rough-in3/26/20183/26/20183/26/2018PPASS
DetailsJim Storey
Lee Phone #: ###-#### framing 1st floor area 3 and 1 ok to cover/ ceilling ok to cover same pending trades// parking garage ceilling ok to insulate.
BLD-Framing/Rough-in3/22/20183/23/20183/23/2018ACANC
DetailsJim Storey
Lee Phone #: ###-####
BLD-Energy code compliance3/7/20183/7/20183/7/2018PPASS
DetailsJim Storey
Lee Scott Phone #: ###-#### exterior walls lobby 1st floor ok to cover.
BLD-Other3/6/20183/7/20183/7/2018APASS
DetailsJim Storey
shaft liner // Lee Scott Phone #: ###-#### stair lids and shafts in corridors ok to cover
BLD-Other3/5/20183/6/20183/6/2018APASS
DetailsJim Storey
shaft insp // lee scott Phone #: ###-#### 4 and 3 ok/ corridor at ada showers on area 1
BLD-Framing/Rough-in3/2/20183/2/20183/2/2018PPASS
DetailsJim Storey
4th floor ceilling all but hvac at se stair
BLD-Framing/Rough-in3/1/20183/1/20183/1/2018PPART
DetailsJim Storey
Lee Phone #: ###-#### backing at handrail/grab bars/ fire stopping stair encloser/exterior insulation/vapor barrior
BLD-Other2/26/20182/26/20182/26/2018PCANC
DetailsJim Storey
Area 1, 1st fl - Lee Phone #: ###-#### 105 & 106 ok to cover
BLD-Other2/23/20182/23/20182/23/2018PPASS
DetailsJim Storey
3dr floor corridor ok
BLD-Other2/23/20182/23/20182/23/2018PPASS
DetailsJim Storey
fire caluking- Lee Phone #: ###-#### area 1# 2nd floor ok / 1st floor area 1 ok all but 105 & 106 nr
BLD-Other2/22/20182/22/20182/22/2018PPART
DetailsJim Storey
Fire caulking, area 1 2nd & 3rd fl - Lee Phone #: ###-####
BLD-Other2/20/20182/21/20182/21/2018APART
DetailsDave Hannah
Lee-fire caulking Phone #: ###-#### corradors levels 1 and 2 0k to cover
BLD-Other2/14/20182/14/20182/14/2018PPASS
DetailsJim Storey
Fire Caulking- Lee Phone #: ###-#### all drops ceillings in rooms area a third floor/ hold on 300 3rd nr
BLD-Other2/13/20182/13/20182/13/2018PPASS
DetailsJim Storey
fire coulking /// Lee scott Phone #: ###-#### fourth floor area a ok
BLD-Other2/12/20182/12/20182/12/2018PCANC
DetailsJim Storey
Lee-fire caulking-area 1 3rd and 4th floors-would like as early as possibly Phone #: ###-#### //cancelled per Lee Scott 11:51am 12/12/18 leg
BLD-Conference2/7/20182/8/20182/8/2018APASS
DetailsJim Storey
Lee-Fire Caulking Phone #: ###-#### 300/trash rms 1,2,3,4th/storage rooms 1-4/area 2 420,423,425,432
BLD-Other2/7/20182/7/20182/7/2018PDEFR
DetailsJim Storey
Lee-Fire Caulking Phone #: ###-####
BLD-Framing/Rough-in2/6/20182/6/20182/6/2018PPASS
DetailsJim Storey
truss repair complet ok unit 403
BLD-Energy code compliance2/6/20182/6/20182/6/2018PPASS
DetailsJim Storey
Lee-area 1 & 2 multiple floors Phone #: ###-#### area 1 2nd floor mech rms ok 1,2,3,4,/ 105 ok /hd ok to cover/ stair 1 insulation ok to cover.
BLD-Other2/6/20182/6/20182/6/2018PNR
DetailsJim Storey
Lee-fire caulkings-area 1 & 2 multiple floors Phone #: ###-####
BLD-Energy code compliance2/5/20182/5/20182/5/2018PPASS
DetailsJim Storey
1st & 2nd floor area 1 - Lee Phone #: ###-#### 204/205/206// mech rm 3rd floor/mech shaft stair#2 ok
BLD-Energy code compliance2/1/20182/1/20182/2/2018PDEFR
DetailsJim Storey
Lee Phone #: ###-####
BLD-Energy code compliance2/1/20182/2/20182/2/2018APASS
DetailsJim Storey
Lee Phone #: ###-####stair 1#/fire chalk 320/322/323/324/325/326/328/330/332// insulation 320/322/323/324/330/332/232/132
BLD-Wall cover1/29/20181/30/20181/30/2018APART
DetailsJim Storey
Fire Caulking - Lee ###-#### pending listing for 21/2 wall/ceilling fire stop for spk.
BLD-Other1/29/20181/29/20181/30/2018PNR
DetailsJim Storey
Fire Caulking - Lee ###-####
BLD-Other1/29/20181/29/20181/29/2018ANR
DetailsJim Storey
Fire Caulking - Lee ###-####
FIRE-Final Inspection1/26/20181/29/20181/29/2018ACANC
DetailsJim Page
Wrong inspector requested, this request is cancelled. Fire colking // Lee Scott Phone #: ###-####
BLD-Framing/Rough-in1/24/20181/25/20181/26/2018APASS
DetailsJim Storey
Lee Scott Phone #: ###-#### Framing: 104/105/106/204/205/206/300/302/303/304/305/306/402/403/405/406

Drop ceiling fire caulking: 123/124/125/126//128.
BLD-Framing/Rough-in1/23/20181/24/20181/24/2018ADEFR
DetailsJim Storey
Lee Scott Phone #: ###-####
BLD-Other1/19/20181/19/20181/19/2018PPASS
DetailsBrandon Shaw
Fire caulking-
BLD-Energy code compliance1/18/20181/18/20181/18/2018PPART
DetailsBrandon Shaw
Units- 100 & 200
BLD-Framing/Rough-in1/18/20181/18/20181/18/2018PPART
DetailsBrandon Shaw
Units- 102, 103, 202, & 203
BLD-Framing/Rough-in1/11/20181/12/20181/12/2018APASS
DetailsJim Storey
Lee Scott Phone #: ###-#### area 2 1st and 2nd as noted ok single units
BLD-Other1/9/20181/10/20181/10/2018ACANC
DetailsJim Storey
Lee-fire caulking in area 3 4th floor Phone #: ###-#### room drops ok insulation ceilling assembly 132 ok to cover
BLD-Framing/Rough-in1/5/20181/5/20181/5/2018PPASS
DetailsJim Storey
Lee Phone #: ###-####132/232/332/432/101/201/301/401
BLD-Framing/Rough-in1/3/20181/4/20181/4/2018PPART
DetailsJim Storey
Area 1 - Lee Phone #: ###-#### c/n
BLD-Energy code compliance12/29/20171/2/20181/2/2018APART
DetailsDave Hannah
Lee Phone #: ###-#### ceiling insulation pull down rooms 125.130.225,230,325,330 and truss repair rm 420 ok
BLD-Other12/28/201712/29/201712/29/2017APART
DetailsDave Hannah
Lee-fire caulking Phone #: ###-#### area 3 3rd floor rooms 308 318 drop ceilings ok to cover.
BLD-Other12/28/201712/28/201712/28/2017PNH
DetailsTony Young
Lee-fire caulking Phone #: ###-####,,phoned.. no answer,, not on site,, others I talked to did not know anything
BLD-Energy code compliance12/21/201712/21/201712/21/2017PPASS
DetailsJim Storey
Lee Phone #: ###-#### 320 322 ok
BLD-Framing/Rough-in12/19/201712/19/201712/19/2017PPASS
DetailsJim Storey
Lee Phone #: ###-#### 125/225/325/130/230/330/ ok
BLD-Energy code compliance12/14/201712/14/201712/15/2017PDEFR
DetailsJim Storey
Lee Phone #: ###-#### out of time
BLD-Energy code compliance12/14/201712/15/201712/15/2017APASS
DetailsJim Storey
lee 328/326/324/323/128/126/124/123
BLD-Framing/Rough-in12/11/201712/11/201712/11/2017PPASS
DetailsJim Storey
Lee Phone #: ###-#### 320/420/423/322/324/326/328/323 mech rms 3 and 4 th ok
BLD-Energy code compliance12/7/201712/8/201712/8/2017APASS
DetailsJim Storey
Lee Scott Phone #: ###-####corridors ok all//124,126,128,123,224,226,228 223 framing ok//insulation ok 120/122,220,222
BLD-Framing/Rough-in12/7/201712/8/201712/8/2017APASS
DetailsJim Storey
Lee Scott Phone #: ###-#### area 1 corridors ok all//124,126,128,123,224,226,228 223 framing ok//insulation ok 120/122,220,222
BLD-Framing/Rough-in12/6/201712/7/201712/7/2017APART
DetailsMike Jordan
Lee Phone #: ###-####. Framing inspection for rooms 124, 126, 123 128, 224,226, 223, 228 and mech rmson 1st. and 2nd. floors in area #2. Needs to provide rated washer boxes and provide Documentation on dryer boxes, patch and fire caulk all pre rock at furred walls. Still needs to provide UL documentation for plastic pipe through penetrations at 3hr. horizontal assembly. Engineer to review removal of OSB at shear wall. Remove low voltage boxes in fire partitions and provide rated box. Ok to insualte exterior walls and ceilings.
BLD-Framing/Rough-in11/30/201712/1/201712/1/2017PPASS
DetailsJim Storey
Lee Phone #: ###-#### ceillings rooms area 3 ok
BLD-Wall Bracing11/30/201712/1/201712/1/2017PPASS
DetailsJim Storey
Lee Phone #: ###-#### area 1 ok
BLD-Framing/Rough-in11/27/201711/28/201711/28/2017APASS
DetailsJim Storey
Area 2 - Lee Phone #: ###-#### area 1 120/220/121/221 stair 2 framing ok
BLD-Other11/20/201711/21/201711/21/2017APASS
DetailsJim Storey
roof nailing- lee Phone #: ###-####
BLD-Other11/17/201711/17/201711/17/2017PPASS
DetailsJim Storey
Fire Caulking- Lee Phone #: ###-#### area 3 1st floor ceilling fire stopping ok to cover drop ceillings
BLD-Energy code compliance11/16/201711/16/201711/17/2017PPART
DetailsJim Storey
Lee Phone #: ###-#### insulation ok 3 hr collors w/pastic pipe require support bothsides of assembly
BLD-Energy code compliance11/13/201711/13/201711/13/2017PNR
DetailsJim Storey
roof nailing and framing// Lee Phone #: ###-####
BLD-Framing/Rough-in11/13/201711/13/201711/13/2017PPART
DetailsJim Storey
roof nailing and framing// Lee Phone #: ###-#### grout/screws/nailling/ exterior 2 hr membrane needed
BLD-Framing/Rough-in11/8/201711/9/201711/9/2017PPASS
DetailsJim Storey
Lee Scott Phone #: ###-#### 4th floor area 3 insulation ok//area 3 framing ok to stair 2#
BLD-Energy code compliance11/7/201711/7/201711/7/2017PPASS
DetailsJim Storey
Lee Phone #: ###-#### insulation and rc ok 3rd floor area 3
BLD-Wall Bracing11/7/201711/7/201711/7/2017PPASS
DetailsJim Storey
Lee Phone #: ###-####area 2 4th floor ok//area 2 3 rd floor ok
BLD-Framing/Rough-in11/1/201711/2/201711/2/2017PPASS
DetailsJim Storey
Lee Phone #: ###-####r/c and insulation 312/309/310/307/308 area 3 3rd floor//sheer walls ok 1st ans 2nd area 2 // roof nailling ok area 2.
BLD-Wall Bracing10/31/201711/1/201711/1/2017PDEFR
DetailsJim Storey
Lee Phone #: ###-#### out of time
BLD-Framing/Rough-in10/27/201710/30/201710/30/2017APASS
DetailsJim Storey
Lee Scott Phone #: ###-####area 3 4 th floor framing ok// area 3 2 nd floor insulation and rc channel ok to cover.
BLD-Other10/26/201710/26/201710/26/2017PPART
DetailsJim Storey
Lee-RC channel area 3-2nd floor Phone #: ###-#### single rm west end of area
BLD-Framing/Rough-in10/24/201710/25/201710/25/2017PPASS
DetailsJim Storey
Lee Scott Phone #: ###-#### corridors 1 and 2 floors area 2// 3dr floor area 3 ok to insulate.
BLD-Energy code compliance10/23/201710/23/201710/23/2017PPASS
DetailsJim Storey
Area 3, 1st floor - Lee Phone #: ###-#### insulation and rc ok to cover
BLD-Other10/23/201710/23/201710/23/2017PPASS
DetailsJim Storey
Roof nailing // Lee Scott Phone #: ###-####
BLD-Energy code compliance10/18/201710/18/201710/18/2017PNR
DetailsJim Storey
Lee scott Phone #: ###-####
BLD-Framing/Rough-in10/16/201710/17/201710/17/2017APASS
DetailsJim Storey
Lee Phone #: ###-#### area 3 level 1 &2 ok to insulate/ firestopping and framing ok
BLD-Framing/Rough-in10/13/201710/16/201710/16/2017PCANC
DetailsJim Storey
Adam-level 1 & 2 area 3 only Phone #: ###-####
BLD-Framing/Rough-in10/12/201710/12/201710/12/2017PPASS
DetailsJim Storey
framing for roof // Evan Phone #: ###-#### a#2 roof ok to cover// sheer wall 4 floor east side stair #2 ok to cover
BLD-Wall Bracing10/10/201710/10/201710/10/2017PPASS
DetailsJim Storey
Lee-dry wall -1st floor area 3 Phone #: ###-####1 and 2 nd lid ok
BLD-Wall Bracing9/29/201710/2/201710/2/2017APASS
DetailsJim Storey
3rd floor, area 3 - lee Phone #: ###-#### ok for nailling
BLD-Other9/25/20179/26/20179/26/2017APART
DetailsDave Hannah
fire wall insp// Lee Scott Phone #: ###-#### 4th floor stair tower 2 ok to move in shear wall
BLD-Other9/14/20179/15/20179/15/2017PPASS
DetailsJim Storey
fire wall // early after noon or late morning // Lee Scott Phone #: ###-#### #2 4th floor east side stair gyp ok / 2nd floor exterior west end straps in place ok to cover no exterior fire protection required.
BLD-Wall Bracing9/12/20179/12/20179/12/2017PPASS
DetailsJim Storey
Lee-dry wall-shear nailing Phone #: ###-####shaft 4th floor area 3 ok/stair well area 3/3 ok corridor lid ok to cover 3/3floor
BLD-Wall cover9/7/20179/8/20179/8/2017APART
DetailsBrandon Shaw
BLD 3, phase 2, area 2, 2nd floor stair well-shear.
Same location, across hallway-mech chase, fire walls
BLD 3, 2nd floor corridoor, 1hr ceiling cover
OK
BLD-Wall Bracing9/5/20179/5/20179/5/2017PPART
DetailsBrandon Shaw
BLD 3, phase 2, stair well 2, 2nd floor shear anfd fire wall.
OK to continue
BLD-Wall Bracing8/30/20178/31/20178/31/2017PPART
DetailsBrandon Shaw
Roof nailing and 2nd floor interior shear panels, Building 3
BLD-Framing/Rough-in8/24/20178/24/20178/24/2017PPASS
DetailsJim Storey
2nd floor // Lee Phone #: ###-#### corridor framing of ceilling ok to pre rock south wing
BLD-Wall cover8/17/20178/18/20178/18/2017APASS
DetailsJim Storey
Lee Phone #: ###-#### pre rock 1st floor corridor 1/2 west to east south side ok
BLD-Wall Bracing8/9/20178/10/20178/10/2017APASS
DetailsJim Storey
Area 3, 4th floor - Lee Phone #: ###-#### exterior sheer ok
BLD-Other8/9/20178/9/20178/9/2017PPASS
DetailsJim Storey
Lee-2 hour firewall Phone #: ###-####east stair first floor
BLD-Wall Bracing8/1/20178/2/20178/2/2017PPASS
DetailsJim Storey
Lee Phone #: ###-####1st floor area b interior sheer ok
BLD-Wall cover7/31/20177/31/20177/31/2017PPASS
DetailsJim Storey
2nd layer west side stair 2 hr ok
BLD-Wall cover7/27/20177/28/20177/28/2017APASS
DetailsJim Storey
Reed Phone #: ###-#### west 1st layer stair 2 ok
BLD-Wall cover7/26/20177/27/20177/27/2017PDEFR
DetailsJim Storey
Reed Phone #: ###-#### out of time
BLD-Wall Bracing7/18/20177/19/20177/19/2017APASS
DetailsJim Storey
Lee Phone #: ###-####stair #2 sheer ok east and west
BLD-Footing7/11/20177/13/20177/13/2017PPASS
DetailsJim Storey
Adam Phone #: ###-#### deck placement #3 ok pending si/ fire collors ok for 3 hr/
BLD-Wall Bracing7/5/20177/6/20177/6/2017APASS
DetailsJim Storey
Reese Phone #: ###-#### south side center 1 st floor wood ext. sheer ok
BLD-Conference6/27/20176/28/20176/28/2017PPART
DetailsJim Storey
Lee Phone #: ###-#### 2nd pt placment fire protection not called for insp.
BLD-Conference5/25/20176/6/20176/6/2017PDONE
DetailsJim Storey
Evan Phone #: ###-####
BLD-Foundation5/25/20175/26/20175/26/2017PPART
DetailsJim Storey
Evan-pre-rebar for podium deck Phone #: ###-#### si on site for bar and pt// fire collors in place for 3 hr protection.
BLD-Foundation5/15/20175/16/20175/16/2017APART
DetailsJim Storey
Wall // Evan Phone #: ###-#### pending si reports
BLD-Foundation5/1/20175/2/20175/2/2017APART
DetailsJim Storey
Evan-partial-pour time 1:00 Phone #: ###-#### placed w/si
BLD-Other4/27/20174/28/20174/28/2017PPEND
DetailsDave Hannah
concrete wall insp// Evan Phone #: ###-#### ok after spec inspection sign off
BLD-Wall Bracing4/26/20174/27/20174/27/2017APART
DetailsJim Storey
Evan Phone #: ###-#### pending si
BLD-Other4/19/20174/20/20174/20/2017APART
DetailsJim Storey
columns // Evan Phone #: ###-#### placed w si pending report
BLD-Conference4/17/20174/20/20174/20/2017ADONE
DetailsJim Storey
Evan-wants it at 10:00 Phone #: ###-####
BLD-Footing4/18/20174/19/20174/19/2017APART
DetailsJim Storey
Evan Phone #: ###-#### ft placed w/si pending reports
BLD-Footing4/17/20174/18/20174/18/2017APASS
DetailsJim Storey
Evan-columns-pour time 10:15 Phone #: ###-#### bar exposer ok
BLD-Footing4/11/20174/12/20174/12/2017APART
DetailsJim Storey
Evan Phone #: ###-#### si east end
BLD-Footing4/10/20174/10/20174/10/2017PPART
DetailsJim Storey
Evan Phone #: ###-#### placed with si pending reports
BLD-Foundation4/3/20174/4/20174/4/2017APART
DetailsJim Storey
rebar // EVAN Phone #: ###-#### ft phase 3 si on site