Permit Information
Permit NumberBLD17-02704
StatusFinaled
Name PROJECT BUILDERS INC
Site Address 7402 W FAIRVIEW AVE
Project NameCVS Pharmacy - New Building
Customer Number 
ePlanReviewYes
Description
(CVS PHARMACY – NEW BUILDING AND TENANT IMPROVEMENT) (DRH17-00113) (CUP17-00018) (CVA17-00022) (10-9-18 PLAN MODIFICATION TO REMOVE THE WEST ACCESSIBLE CURB RAMP AT WILSHIRE DRIVE AND TO ADJUST THE VEHICLE ACCESS TO CONNECT INTO THE EXISTING VALLEY GUTTER SO THAT THE DISTURBANCE TO THE ADJACENT PROPERTY OWNER’S DRIVEWAY IS MINIMIZED. APPROVAL BY ACHD IS REQUIRED.) (8-22-18 PLAN MODIFICATION TO CONSTRUCT AN EXTERIOR RAMP ACCESSIBLE TO THE DISABLED [1:20 MAX. SLOPE], TO MODIFY THE FORMERLY PROPOSED EXTERIOR STEPS TO ADD MORE RISERS AND TREADS, TO CHANGE THE ROUTING OF STORM WATER DRAIN LINES, AND TO ADD A STORM WATER INFILTRATION SWALE. THE RAMP IS REQUIRED TO BE ACCESSIBLE TO THE DISABLED AS DEFINED BY CURRENT ACCESSIBILITY STANDARDS. HANDRAILS ARE REQUIRED ON THE STAIRWAY.) The fire sprinkler system is used for fire area. Three buildings and the East end of an existing retail sales building will be demolished to accommodate this new development. To construct a 12,648 square foot building (14,476 square feet including the 1,828 square foot enclosed mezzanine) to be used as a pharmacy and for retail sales. Work is to include concrete footings, concrete foundations, concrete slab on grade with slab edge insulation, masonry exterior walls, insulation installed on the inside of the masonry exterior walls, EIFS installed on the outside of masonry exterior walls, steel roof joists, steel roof deck, insulation installed on top of the roof deck, a roof membrane, exterior windows, exterior doors, an exterior roll-up door at the receiving area, suspended acoustical ceilings, gypsum board soffits, a VRC (Vertical Reciprocating Conveyor) with shallow pit and gates, a horizontal sliding security grill at the pharmacy, a hatch and ladder to the roof, interior nonbearing walls, two toilet rooms accessible to the disabled, display shelves, millwork, and finishes. Mezzanine work includes concrete footings, steel columns, steel girders, steel beams, concrete floor on a steel deck, and a steel stairway. Special Inspection is required for soils, concrete, masonry, anchors post-installed in hardened concrete or masonry, welding, and EIFS. All of the storage and display shelves will be less than 8 feet high. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is intended to establish a Certificate of Occupancy for this tenant and for the entire building. The fire sprinkler system is required to comply with NFPA 13 and the fire alarm system is required to comply with NFPA 72 as regulated by the Fire Department. Separate fire sprinkler permits and fire alarm permits shall be obtained prior to beginning any modification or installation work on such systems. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final11/27/201811/27/201811/27/2018PPASS
DetailsMike Jordan
Mark Phone #: ###-####. Ok for perm occ.
BLD-Final11/1/201811/2/201811/2/2018PPART
DetailsJim Sly
Mark Phone #: ###-####
OK for Temp. Occ. Zoning on Bond. OK for Perm Occ. when ........Zoning and ACHD signs off for Perm. Occ. Talked to Bill Gaul at ACHD 208 387 6100.
FIRE-Final Inspection11/1/201811/2/201811/2/2018APASS
DetailsTroy Cobbley
Life safety passed

Mark Phone #: ###-####
FIRE-Final Inspection11/1/201811/1/201811/1/2018PCANC
DetailsTroy Cobbley
Mark Phone #: ###-####
FIRE-Final Inspection10/30/201810/31/201810/31/2018PFAIL
DetailsTroy Cobbley
Still need all of the emergency lights over the sales floor repaired and tested.

Mark Phone #: ###-####
BLD-Final10/29/201810/30/201810/30/2018PNR
DetailsJim Sly
Mark Phone #: ###-####
FIRE-Final Inspection10/29/201810/30/201810/30/2018AFAIL
DetailsTroy Cobbley
Repair the exit discharge light at the stockroom exit door, provide exit sign on mezzanine, provide all emergency lighting as per the city approved plans.

Mark Phone #: ###-####
FIRE-Conference10/2/201810/2/201810/2/2018PDONE
DetailsTroy Cobbley
Mark and I went over the typical life safety requirements. He did not have the updated plans or any of the small documents.

Mark Phone #: ###-####
BLD-Ceiling Grid Inspection9/7/20189/7/20189/10/2018PPASS
DetailsJim Sly
Mark Phone #: ###-####
BLD-Ceiling Grid Inspection8/30/20188/30/20188/30/2018PPEND
DetailsDave Hannah
just to do boarder tiles// Mark Phone #: ###-#### ok to cover main area after other trades sign off
BLD-Framing/Rough-in8/10/20188/13/20188/13/2018APASS
DetailsJim Storey
Mark Phone #: ###-#### pharm and receiving areas ok to cover
BLD-Framing/Rough-in8/2/20188/6/20188/6/2018APART
DetailsJim Sly
Mark ###-####
OK to cover Front Canopy, Corridor, restrooms and locker room.
BLD-Framing/Rough-in7/20/20187/20/20187/20/2018PPART
DetailsJim Sly
Mark Phone #: ###-####
South 2/3 of bldg....OK
BLD-Framing/Rough-in7/5/20187/6/20187/6/2018APART
DetailsJim Sly
Mark Phone #: ###-####
OK to rock.......Elevator, Mezzanine and Walls 4 foot down from Ceiling.
BLD-Conference6/20/20186/20/20186/21/2018PDONE
DetailsJim Sly
Mark Phone #: ###-####
BLD-Other5/22/20185/22/20185/23/2018PPART
DetailsJim Sly
Mark -a rebar placement and masonery wall- 8 foot lift on columns and 12 ft lift on drive thru Phone #: ###-####
BLD-Other5/21/20185/21/20185/21/2018PPART
DetailsJim Sly
rebar in masonry wall // 24 foot lift west wall // Mark Phone #: ###-####
OK pending MTI insp, tests and approvals.
BLD-Other5/18/20185/18/20185/21/2018PPART
DetailsJim Sly
Mark Project--rebar replacemt masonery wall-24 foot lift so and west walls Phone #: ###-####
MTI on site
BLD-Other5/17/20185/17/20185/17/2018PPART
DetailsJim Sly
Mark-masonary wall to grout south and west wall 20'' Phone #: ###-####
OK pending MTI special inspection,tests and approvals.
BLD-Foundation5/15/20185/16/20185/16/2018ACANC
DetailsJim Sly
16ft lift south wall Rebar // Mark Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Wall Bracing5/11/20185/11/20185/11/2018PPART
DetailsJim Sly
Mark-wall rebar placing-south wall and west wall 8 foot lift Phone #: ###-####MTI on site
BLD-Other5/9/20185/10/20185/10/2018APART
DetailsJim Sly
rebar- 4ft lift south wall Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Foundation5/7/20185/8/20185/8/2018PPART
DetailsJim Sly
Rebar... 24ft lift north wall // Mark Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Foundation5/7/20185/7/20185/7/2018PPART
DetailsBrandon Shaw
Rebar.. 24 ft. lift east wall
BLD-Foundation5/4/20185/4/20185/6/2018PPART
DetailsJim Sly
Mark-masonary rebar-pour time 2:00 noth wall 20 ft lifts Phone #: ###-####
BLD-Footing5/2/20185/3/20185/3/2018PPART
DetailsJim Sly
Masonry wall, rebar, 20ft lift N & E walls - Mark Phone #: ###-####
MTI on site
BLD-Foundation5/1/20185/2/20185/2/2018PPASS
DetailsJim Sly
Rebar... 16ft list mes.wall north and est // Mark Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Other4/30/20184/30/20184/30/2018PPART
DetailsBrandon Shaw
rebar placement & masonry wall east and north walls
OK pending MTI special insp, tests and approvals.
BLD-Footing4/27/20184/27/20184/27/2018PPART
DetailsJim Sly
sub-grade rebar - Mark Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Foundation4/27/20184/27/20184/27/2018PPART
DetailsJim Sly
Mark-8'' lift-east wall and north wall Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Foundation4/25/20184/25/20184/25/2018PPART
DetailsJim Sly
Mark-rebar on 4ft lift masonary wall on east and north walls Phone #: ###-####
OK pending MTI special inspection, Tests and Approvals.
BLD-Footing4/23/20184/23/20184/23/2018PPART
DetailsJim Sly
Mark-rebar Phone #: ###-####
OK pending MTI special insp, tests and approvals.
BLD-Footing4/17/20184/18/20184/18/2018PPART
DetailsJim Sly
Mark-pour time 2:30 Phone #: ###-####
Exterior Wall footings....OK pending MTI special inspections, tests and approvals.