Permit Information
Permit NumberBLD17-02754
StatusIssued
Name MARK GUHO CONSTRUCTION COMPANY
Site Address 2404 W BANK DR
Project NameBank Drive - Suite #200 B
Customer NumberBLD17-02828
ePlanReviewYes
Description
**(BANK DRIVE – SUITE #200 B)** (2 BUILDING PERMITS UNDER BLD17-02754 IN EPLAN) Permit is to remodel an existing 2,071 sq. ft. tenant space on the second floor by dividing it into two separate tenant spaces, this tenant space is to be 695 sq. ft. and the remaining 1,376 sq. ft. is to be an unoccupied tenant space created under BLD17-02828. Approval is contingent upon adhering to the approved plans on file. Work to include: construction of select interior nonbearing wall to demise tenant spaces and interior finishes in compliance with chapter 8 of the 2012 IBC. This building is fully Fire Sprinklered with an approved Fire Alarm system. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final9/29/20179/29/20179/29/2017PPASS
DetailsJim Storey
David Phone #: ###-####
FIRE-Final Inspection9/29/20179/29/20179/29/2017PPASS
DetailsJim Page
Fire sprinkler inspection complete, no fire alarm modifications, fire extinguisher is in common area with a current inspection tag. Final life fire safety inspection for area of work passed/complete.
FIRE-Conference9/21/20179/22/20179/22/2017ADONE
DetailsJim Page
Fire conference complete
BLD-Final8/29/20178/30/20178/30/2017PNR
DetailsJim Storey
David Phone #: ###-####
FIRE-Final Inspection8/29/20178/30/20178/30/2017AFAIL
DetailsTroy Cobbley
No city approved plans on site. I performed a courtesy inspection and noted expired fire extinguisher and non-functional exit sign/emergency light in corridor. I also noted that the existing sprinkler system needs modifications to meet current code. There is exposed cpvc piping with pendants that are located too far from deck since the ceiling has been removed.

David Phone #: ###-####
BLD-Framing/Rough-in8/16/20178/16/20178/16/2017PPASS
DetailsJim Storey
David Phone #: ###-#### iia type of const not corect