Permit Information
Permit NumberBLD17-02915
StatusFinaled
Name RRC CONTRACTORS
Site Address 10485 W FAIRVIEW AVE
Project NameIdaho Youth Ranch
Customer Number 
ePlanReviewYes
Description
(IDAHO YOUTH RANCH) //Plan modification to remove interior door leading to office #105, to add a double swinging door leading to the restroom area, remove the exterior rear double door and replace with a single door and infill with wall CMU. Note: reduced occupant load at the retail area using Table 1004.1.2 of the 2015 IBC. 2-15-2018 JG// Permit is to remodel an existing 12,765 sq. ft. space for retail use within an existing 83,904 sq. ft. building. Shell and core remodel done under BLD17-01449. Approval is contingent upon adhering to the approved plans on file. Work to include: break room millwork, (4) new dressing rooms of which one is an accessible dressing room for the disabled, removal select half wall at the receiving area and add door openings at the office leading to the mercantile space and opening at break room leading to the egress hallway and plumbing work. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. Note: The fire sprinkler system is used for unlimited area of the building AND to allow 3-hr fire barrier walls in lieu of fire walls. The fire sprinkler system is NOT allowed to be used for building area increase for A Occupancies. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final5/16/20185/16/20185/16/2018PPASS
DetailsMike Jordan
shell and core permit Bld17-01449 is finaled, modifiations are done // Bruce Rolfe Phone #: ###-####. Ok for perm occ. No card to sign.
BLD-Final5/14/20185/15/20185/15/2018ACANC
DetailsMike Jordan
Derek Phone #: ###-####. Will reschedule.
FIRE-Final Inspection5/14/20185/14/20185/14/2018PPASS
DetailsJim Page
Exit discharge light is installed at main entry, final life fire safety inspection complete.

Derek Phone #: ###-####
BLD-Aging Inspection4/18/20184/18/20184/18/2018 PEND
DetailsMike Jordan
BLD-Final2/16/20182/16/20182/16/2018PPART
DetailsJim Sly
Bruce Phone #: ###-####
OK for Temp Occ. OK for Perm Occ .When Architect submits drawing to the city which includes new double door installed in CMU wall East end. Installation appears to be typical of other new doorways installed in CMU wall per Architect/Engineer, Fire signs off for Perm Occ. and Building Exterior store front is completed.
FIRE-Final Inspection2/16/20182/16/20182/16/2018PPART
DetailsTroy Cobbley
A temporary for life safety is being given until the exit discharge light is installed at the main exit.


Bruce Phone #: ###-####
BLD-Final2/15/20182/15/20182/15/2018PNR
DetailsMike Jordan
Late afternoon - Bruce Phone #: ###-####
FIRE-Final Inspection2/15/20182/15/20182/15/2018PCANC
DetailsTroy Cobbley
Plans are still in review

Late afternoon - Bruce Phone #: ###-####
FIRE-Final Inspection2/6/20182/6/20182/6/2018PCANC
DetailsTroy Cobbley
Hugo Phone #: ###-####
FIRE-Final Inspection2/1/20182/1/20182/1/2018PFAIL
DetailsTroy Cobbley
Provide fire extinguisher on the mezzanine, provide a exit discharge light at the main exit, provide double door with panic hardware at the rear exit as per the T.I. plans

Hugo Phone #: ###-####
BLD-Other1/31/20182/1/20182/1/2018AFAIL
DetailsMike Jordan
CMU // Hugo Phone #: ###-####. New openings in interior CMU walls not done per approved plans and engineering. engineer of record to accept in place work and provide letter or provide approved fix or have in place work removed and installed per the approved drawings. Correction notice issued.