Permit Information
Permit NumberBLD17-03339
StatusFinaled
Name WAYNCO CONSTRUCTION CO
Site Address 7222 W OVERLAND RD
Project NameMcDonald's Remodel
Customer Number1801
ePlanReviewYes
Description
(MCDONALD’S – EXTERIOR AND INTERIOR REMODEL) (DRH17-00397) (CZC09-00070) This building does not have a fire sprinkler system. To remodel the existing public restrooms within an existing 4,480 square foot restaurant building. Some walls within the restrooms will be demolished and new toilet stalls will be installed. Both restrooms are required to be accessible to the disabled as defined by current standards. The existing customer service counter will be removed and replaced with a new customer ordering counter and a new pick-up counter. A new suspended ceiling system will be installed and a new gypsum board ceiling will be installed in the restrooms. Exterior work includes raising existing wall parapets by 2 feet 6 inches; installing some new exterior wall finishes; installing new R-25 continuous roof insulation on top of the roof deck below a new membrane roof covering; installing drive thru order canopies, a gateway, and menu boards; constructing new concrete sidewalks, curb ramps, and landing at doors; constructing a new sidewalk to the public sidewalk; and moving accessible parking spaces. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. This permit is intended to create a new Certificate of Occupancy for this tenant. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final3/22/20183/22/20183/22/2018PPASS
DetailsMike Jordan
Curt Phone #: ###-#### or Justin ###-####. OK for temp occ. Will be ok for perm occ. once zoning signs perm.
BLD-Final3/21/20183/22/20183/22/2018PCANC
DetailsMike Jordan
Kurt Phone #: ###-####. Wrong entry. Inspection has been rescheduled.
BLD-Conference3/22/20183/22/20183/22/2018PCANC
DetailsMike Jordan
FIRE-Final Inspection3/20/20183/21/20183/21/2018APASS
DetailsTroy Cobbley
life safety passed


request first thing in AM // Justin Boyer Phone #: ###-####
FIRE-Final Inspection3/16/20183/19/20183/19/2018PFAIL
DetailsTroy Cobbley
Remove the dead bolt on the door between dining and the playland area and also install an exit sign as per the plans, mount the fire extinguisher in the Playland area, repair the two emergency lights in the Kitchen area and finish installing the exit discharge light out the back Kitchen door, install the Occupant Load signs (two). The hood suppression and fire extinguishers are current with inspections.

Justin Phone #: ###-####
BLD-Ceiling Grid Inspection3/9/20183/9/20183/9/2018PPART
DetailsBrandon Shaw
OK for perimeter cover,
BLD-Ceiling Grid Inspection3/8/20183/8/20183/8/2018PPASS
DetailsMike Jordan
Justin Phone #: ###-####
BLD-Ceiling Grid Inspection3/1/20183/2/20183/2/2018APART
DetailsBrandon Shaw
Partial for playland area- OK to cover perimeter only
BLD-Framing/Rough-in2/23/20182/26/20182/26/2018APASS
DetailsMike Jordan
justin Phone #: ###-####. Interior steel stud framed walls and hardlid for restrooms.
BLD-Framing/Rough-in2/22/20182/23/20182/23/2018PNR
DetailsMike Jordan
Justin Phone #: ###-####
BLD-Framing/Rough-in2/12/20182/13/20182/13/2018APASS
DetailsMike Jordan
Justin Phone #: ###-####. Remainder of exterior band ok. Also new kicker wall for parapet ok.
BLD-Framing/Rough-in2/8/20182/9/20182/9/2018APART
DetailsDave Hannah
Justin-partial Phone #: ###-#### ok to cover ext band around building also ok to cover parapet
BLD-Footing2/8/20182/9/20182/9/2018APASS
DetailsDave Hannah
Justin Phone #: ###-####
BLD-Framing/Rough-in2/2/20182/5/20182/5/2018APASS
DetailsMike Jordan
Justin Phone #: ###-####. Parapet exetesion framing ok.