Permit Number | BLD17-04659 |
Status | Finaled |
Name |
EAGLE MATERIAL HANDLING LLC
|
Site Address |
11343 W PRESIDENT DR
|
Project Name | Innovative Air Racking |
Customer Number | |
ePlanReview | Yes |
Description |
(INNOVATIVE AIR **RACKING**) **Permit to add storage racking in an existing warehouse. Work to include: installation of prefabricated 10 ft, 12 ft, and 16 ft tall storage racking, including seismic bolting to existing slab for all racking, mounted at least 1'-0" from building structure. Anticipated maximum storage height to be 20 feet. Racking installed in front of doors must maintain 80” min. clearance. Tenant Permit under BLD17-04612, in review. Approval of this permit is contingent on adhering to approved plans and engineering. The design, testing and utilization of industrial steel storage racks shall be in accordance with the RMI Specification for the Design, Testing and Utilization of Industrial Steel Storage Racks. Special inspections required per attached form 310. The structural design by Curry-Riehl and Associates is attached. This is a fully fire sprinklered building. Any alterations to the sprinkler system will require a separate permit and shall comply with NFPA 13 as regulated by the fire department. **JAR**
|