Permit Information
Permit NumberBLD18-00313
StatusFinaled
Name TWO PLANK CONSTRUCTION
Site Address 224 N 9TH ST
Project NameMeriwether Cider House - TI
Customer NumberBLD18-00723 INT DEMO
ePlanReviewYes
Description
(MERIWETHER CIDER HOUSE – TENANT IMPROVEMENT – 1ST AND 2ND STORY) (CZC18-00016) This building does not have a fire sprinkler system. Interior nonstructural demolition work within this tenant space was done under permit BLD18-00723. To remodel an existing 1,261 square foot tenant space (858 square feet 1st story and 403 square feet 2nd story) for a new bar tenant. Work is to include a new overhead roll-up window in an existing exterior window opening with a new counter below it, a new structural wood header and trimmers to support the window, a new exit door to Bannock Street, new sister floor joists attached to the existing 2nd story floor joists to accommodate a 100 psf live load, a walk-in cooler, interior nonbearing walls, a toilet room on the 2nd story accessible to the disabled, an upgraded existing 1st story toilet room accessible to the disabled, an interior bar counter, millwork, and finishes. The 2nd story occupant load is 23, the 1st story occupant load is 32, and the future sidewalk seating occupant load is 12. Outdoor seating and the surrounding fence are not allowed to obstruct the egress path from this tenant space. The work is required to comply with the approved drawings, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Conference9/7/20189/7/20189/7/2018PPASS
DetailsMike Jordan
TJ Phone #: ###-####. Ok for perm occ.
BLD-Final9/7/20189/7/20189/7/2018APASS
DetailsMike Jordan
TJ - Per MIke J ok for perm occ (BLD- conference) Phone #: ###-####
BLD-Final8/23/20188/23/20188/23/2018PPEND
DetailsDave Hannah
TJ Phone #: ###-####ok for tco
FIRE-Final Inspection8/22/20188/23/20188/23/2018APASS
DetailsJim Page
Pteviously noted items have been completed, sticker above main entry will have a signage ready "Door to remain unlocked while building is occupied". Final life fire safety inspection complete.

TJ Phone #: ###-####
BLD-Final8/21/20188/22/20188/23/2018PNR
DetailsDave Hannah
TJ Phone #: ###-####
FIRE-Final Inspection8/21/20188/22/20188/22/2018AFAIL
DetailsJim Page
Mount fire extinguishers in discussed location. Install maximum occupancy placard. Install exterior emergency lighting as discussed.

TJ Phone #: ###-####
FIRE-Conference8/14/20188/15/20188/15/2018ADONE
DetailsJim Page
Fire conference complete.

TJ Phone #: ###-####
BLD-Conference8/2/20188/2/20188/2/2018PDONE
DetailsDave Hannah
TJ Phone #: ###-####
BLD-Framing/Rough-in6/26/20186/27/20186/27/2018PPASS
DetailsDave Hannah
TJ Phone #: ###-####
BLD-Conference6/19/20186/20/20186/21/2018PDONE
DetailsDave Hannah
TJ Phone #: ###-####