BLD-Final | 11/19/2018 | 11/20/2018 | 11/20/2018 | A | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick
|
DOC - Permit Finaled | 11/20/2018 | 11/20/2018 | 11/20/2018 | P | PASS |
Brandon Shaw
|
|
|
|
BLD-Blower Door Test Results | 11/20/2018 | 11/20/2018 | 11/20/2018 | A | DONE |
Brandon Shaw
|
|
|
ACH50- 3.56
|
BLD-Final | 11/15/2018 | 11/16/2018 | 11/16/2018 | A | NR |
Jim Sly
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Energy code compliance | 9/27/2018 | 9/28/2018 | 9/28/2018 | A | PASS |
Brandon Shaw
|
|
|
Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Framing/Rough-in | 9/27/2018 | 9/28/2018 | 9/28/2018 | A | PASS |
Brandon Shaw
|
|
|
Corrections SAT...
|
BLD-Other | 9/26/2018 | 9/27/2018 | 9/26/2018 | A | PASS |
Brandon Shaw
|
|
|
Soffit Phone #: ###-#### Inspection requested via web by Kyle Seick
|
BLD-Framing/Rough-in | 9/25/2018 | 9/26/2018 | 9/26/2018 | A | PASS |
Brandon Shaw
|
|
|
Corrections SAT...
OK to insulate
|
BLD-Framing/Rough-in | 9/24/2018 | 9/24/2018 | 9/24/2018 | P | CANC |
Brandon Shaw
|
|
|
Phone #: ###-#### >> Inspection requested via web by Kyle Seick Inspection cancelled from web by: Kyle Seick
|
BLD-Framing/Rough-in | 9/20/2018 | 9/21/2018 | 9/21/2018 | P | FAIL |
Brandon Shaw
|
|
|
Anchor bolts to be no more that 12" from ends of sill plate... H2 header at kitchen window missing... Hold downs and straps to be as per plans... Provide Engineering for B3 and B5 beams not installed as per plans... Provide Truss Engineering
|
BLD-Wall Bracing | 8/30/2018 | 8/31/2018 | 8/31/2018 | A | PART |
Brandon Shaw
|
|
|
Work in progress Anchor bolts, hold downs and straps to be as per plans
|
BLD-Foundation | 7/2/2018 | 7/2/2018 | 7/2/2018 | P | PASS |
Brandon Shaw
|
|
|
Work in progress
|
BLD-Footing | 6/28/2018 | 6/29/2018 | 6/29/2018 | A | PASS |
Brandon Shaw
|
|
|
Work in progress
|