Information based on query as of Tuesday, July 23, 2024.
Permit Information
Permit NumberBLD18-01037
StatusFinaled
Name WAYNCO CONSTRUCTION CO
Site Address 6574 S FEDERAL WAY
Project NameMcDonald's Remodel
Customer Number 
ePlanReviewYes
Description
(MCDONALD’S – EXTERIOR AND INTERIOR REMODEL) (DRH18-00098) This building does not have a fire sprinkler system. To remodel the 2,303 square foot public area of an existing 4,017 square foot restaurant building. No work in the kitchen area is proposed under this permit. Work is to include upgrading two toilet rooms to be accessible to the disabled, suspended acoustical ceilings, and new interior finishes. Exterior work to the building includes removing the existing mansard roof at the perimeter of the building and removing the entrance canopy, lowering some existing parapets, placing a new concrete footing, constructing new exterior furred walls, constructing new parapets and extending the height of existing parapets, installing new wall finishes at extended and new parapets, and installing new aluminum trellis/awning systems with tie-back rods and fascia. Existing roof joists will be strengthened to support a new parapet. Site work includes a gateway sign, digital pre-browse board, customer order canopy, a digital menu board, and related concrete foundations. Special Inspection is required for concrete and for anchors post-installed in hardened concrete. Two accessible parking spaces will be relocated and upgraded to comply with current accessibility standards. This permit is intended to establish a new Certificate of Occupancy for the entire building. The work is required to comply with the approved drawings, with the structural design, with the plan review report, and with all applicable codes and ordinances. **CJW**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/23/20191/24/20191/24/2019APASS
DetailsJim Storey
Justin Boyer is the Super for this job, please contact him if you need any one on site. Thanks Phone #: ###-#### Inspection requested via web by Curtis Start
DOC - Permit Finaled1/24/20191/24/20191/24/2019PPASS
DetailsJim Storey
BLD-Other9/7/20189/10/20189/10/2018APASS
DetailsJim Storey
early please for rebar for drive -thru - Curtis Phone #: ###-####
BLD-Ceiling Grid Inspection8/20/20188/21/20188/21/2018APART
DetailsJim Storey
Justin Phone #: ###-#### ok pending ele
BLD-Framing/Rough-in8/15/20188/16/20188/16/2018APASS
DetailsJim Storey
As early as possible please.
Thanks,
A. Inspection requested via web by Austin Goodrich exterior nailling ok to cover.
BLD-Foundation8/13/20188/14/20188/14/2018APASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Austin Goodrich
BLD-Framing/Rough-in8/9/20188/10/20188/10/2018APASS
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Austin Goodrich ok to cover exterior roof framing