Permit Information
Permit NumberBLD18-01167
StatusFinaled
Name HHS CONSTRUCTION LLC
Site Address 4525 E LOGGER DR
Project NameWillow Cr 2 story Modern Metro
Customer Number 
ePlanReviewYes
Description
Permit for the construction of a new 2860 sq. ft., two story (first story 1229 sq. ft., second story 1631 sq. ft.) single family dwelling with 5 bedrooms, 3.5 bathrooms, approximately 85 sq. ft. of covered patio/porch and a 583 sq. ft. attached garage per the approved plans, plan review report and any notations. SP-01 zoning and setbacks per planning. ***BJM***
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final1/2/20191/3/20191/3/2019PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
DOC - Permit Finaled1/3/20191/3/20191/3/2019PPASS
DetailsBrandon Shaw
BLD-Blower Door Test Results1/2/20191/3/20191/3/2019PDONE
DetailsBrandon Shaw
ACH50- 3.46
BLD-Final1/2/20191/2/20191/2/2019PCANC
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Blower Door Test Results1/2/20191/2/20191/2/2019PCANC
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Gus Brandon
BLD-Other10/31/201811/1/201810/31/2018APASS
DetailsBrandon Shaw
Soffit. Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Energy code compliance10/31/201810/31/201810/31/2018PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Framing/Rough-in10/31/201810/31/201810/31/2018APASS
DetailsBrandon Shaw
Corrections SAT...
BLD-Framing/Rough-in10/26/201810/29/201810/29/2018AFAIL
DetailsBrandon Shaw
Provide complete set of floor and roof truss Enigneering...
Provide full bearing path to foundation, with squash blocks between floors and blocking...
See red paint...
BLD-Wall Bracing10/25/201810/25/201810/25/2018PPASS
DetailsBrandon Shaw
Phone #: ###-#### Inspection requested via web by Kyle Seick
BLD-Wall Bracing10/23/201810/23/201810/23/2018PFAIL
DetailsBrandon Shaw
Covered with Tyvex...
No plans...
Hold downs are to be as per plans and installed per Man. Rec...
Anchor bolts to be no more than 12" from ends of sill plates
BLD-Wall Bracing10/17/201810/18/201810/18/2018AFAIL
DetailsJim Storey
Phone #: ###-#### Inspection requested via web by Kyle Seick covered w/o insp
BLD-Foundation8/14/20188/15/20188/15/2018APASS
DetailsBrandon Shaw
As late as possible Phone #: 2084207023 >> Inspection requested via mobile web by Dion Connell
BLD-Footing8/13/20188/14/20188/14/2018APASS
DetailsBrandon Shaw
Work in progress