Permit Information
Permit NumberBLD18-02561
StatusFinaled
Name LAYTON CONSTRUCTION
Site Address 6707 S EISENMAN RD Unit: 100
Project NameIntegrity Audio Visual Ste 100
Customer Number 
ePlanReviewYes
Description
(INTEGRITY AUDIO VISUAL – GOWEN INDUSTRIAL PARK – WAREHOUSE BUILDING "A" - SUITE #100) The fire sprinkler system is used for building area increase and for fire area. Permit is to construct tenant improvements within a new 51,408 sq. ft. building shell (Shell under BLD17-03872) to make a 10,368 sq. ft. tenant space for office and warehouse use (office is 1,904 sq. ft. + warehouse is 8,646 sq. ft.). Approval is contingent upon adhering to the approved plans on file. Work to include: interior concrete slab, construction of interior non-bearing walls to make (3) offices, a conference room, a storage closet, (2) accessible restrooms, IT closet, a hall, open office area, a reception area and a warehouse area, new door/door frames, millwork, new suspended acoustic and gypsum ceiling, light fixtures, electrical work, plumbing work, mechanical work and interior finishes in compliance with Ch. 8 of the current IBC. This building is fully Fire Sprinklered. Any alterations or modifications to the buildings Fire Sprinkler or Fire Alarm system WILL REQUIRE A SEPARATE PERMIT and shall be installed per NFPA 13 & NFPA 72 as regulated by the Boise Fire Department. **JG**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
FIRE-Final Inspection10/29/201810/29/201810/29/2018PPASS
DetailsJim Page
Life fire safety inspection for racking permit associated with tenant complete. Final life fire safety inspection for area of work complete.
BLD-Final10/25/201810/26/201810/26/2018PPASS
DetailsJim Storey
Tim Phone #: ###-#### pending fire
FIRE-Final Inspection10/25/201810/26/201810/26/2018APART
DetailsJim Page
Previously noted items have been corrected, life fire safety inspection for this permit is complete. Racking permit (BLD18-03747) is issued to the tenant, life fire safety can be finaled once racking permit is completed.

Tim Phone #: ###-####-racking is in and will be anchored on Friday
FIRE-Final Inspection10/23/201810/24/201810/24/2018PFAIL
DetailsJim Page
Provide emergency lighting in receptionist area (emergency lighting provided thoughout tenant space, none shown in receptionist lobby) Racking permit BLD18-03747 needs to be finaled for life safety before tenant space life fire safety inspection can be completed.

Tim Phone #: ###-####
BLD-Ceiling Grid Inspection10/8/201810/9/201810/9/2018PPASS
DetailsJim Storey
Tyler Phone #: ###-####
BLD-Framing/Rough-in9/10/20189/10/20189/10/2018PPASS
DetailsJim Storey
Quinten Phone #: ###-####