(THE DUTCH GOOSE) Permit for tenant improvements to an existing 4,088 sq ft restaurant. Work to include: demolition of existing interior, non-structural partition walls, soffit, ceiling, and kitchen; new exterior window, and façade at corner; installation of new interior non-bearing partition walls and doors; new kitchen equipment; new restrooms; plumbing, mechanical, and electrical work; new millwork and interior finishes in compliance with Ch. 8 of the 2015 IBC. Special inspections required per the attached Form 310 for anchors into existing construction. Canopies over windows are not included in this permit; a separate permit is required for the installation of the canopies. This building is NOT Fire Sprinklered**JAR**
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
BLD-Final2/22/20192/22/20192/22/2019PPASS
DetailsTony Young
Anthony Phone #: ###-####
FIRE-Final Inspection2/21/20192/21/20192/21/2019PPASS
DetailsJim Page
Previously noted items have been corrected, final life fire safety inspection complete.

Anthony Phone #: ###-####
FIRE-Final Inspection2/20/20192/20/20192/20/2019PFAIL
DetailsJim Page
Provide exit signage and emergency lighting on the southside enclosed patio. Provide emergency lighting in corridor between restrooms. Provide signage over the top of the main entry reading "Door to remain unlocked while building is occupied". South door swings the wrong direction for path of travel, need to correct door swing and install panic type door hardware per building fire code review comments. Place fire extinguishers in discussed locations.

Anthony Phone #: ###-####
BLD-Framing/Rough-in2/5/20192/6/20192/6/2019APASS
DetailsTony Young
Anthony Phone #: ###-####,, exterior corner frame ok
BLD-Framing/Rough-in1/29/20191/30/20191/30/2019APART
DetailsTony Young
Antonio Phone #: ###-####,, rest room walls ok to cover,, all interior walls ok